answersLogoWhite

0


Best Answer

Your 11 kv to 220 volts represents a 50 to 1 stepdown. (There is 50 times more voltage in the primary than in the secondary.) You'll have to have a 50 to 1 turns ratio. That means 1/50 of the number of turns in the primary will be in the secondary, and that is 64 turns.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar
More answers
User Avatar

Anonymous

Lvl 1
4y ago

100kv

This answer is:
User Avatar

User Avatar

Anonymous

Lvl 1
4y ago

200kv

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: A transformer is used to step down a voltage of 11kv to 220 volts. Given that the primary coil has 3200 turns what is the number of turns on the secondary coil?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

HOW do I SELECT A STEP DOWN TRANSFORMER?

By looking to the number of turns in the Primary and Secondary Coils. "A Step down transformers are designed to reduce electrical voltage. Their primary voltage is greater than their secondary voltage. This kind of transformer "steps down" the voltage applied to it."


Difference between input and output transformer?

The 'input' side of a transformer is called its 'primary' side, whereas the 'output' side is termed its 'secondary' side. The ratio of its secondary to primary voltage is equal to the ratio of the number of turns in the secondary windings to the number of turns in the primary winding. So if, for example, a transformer's secondary winding has twice as many turns as its primary winding, then the secondary winding will produce twice the voltage applied to the primary winding.


How do you work out the secondary voltage in a transformer?

The voltage ratio is the same as the turns ratio for an ideal transformer, and most transformers are close to being ideal. So use the following equation:Vs/Vp = Ns/Np


How do you find the secondary to primary transformer voltage ratio?

Turns Ratio = (Primary turns / Secondary turns) To calculate the turns ratio you have to actually know the number of turns or wraps on the primary and secondary coils. Nobody knows that usually the manufacture of the transformer doesn't even know. So what you can use as and equivalent is to calculate the voltage ratio. So what you typically need to look for is the Input voltage and divid it by the output volatge. Usually that would be as follows; (Primary Voltage/Secondary Voltage) = Voltage Ratio


What changes a low voltage into a higher voltage?

The step up transformer is used to change the voltage from high to low or low to high voltage by eitherincreasing the number of inding or reducing the number of winding in the transformer,thus when the winding reduced on side of primary winding and ingreasing number of winding on secondary side it means the transformer should be step up transfo0rmer,and when the you increase number of turnsin primary side and reduce turned on secondary sidde the transformer said to be step down transformer

Related questions

How many turns in secondary coil in Transformer?

It depends on the type of transformer.If it is a step up transformer the number of turns in secondary side is higher than primary.Stepdown means it will have fewer number of windings on the secondary side turns when compared with the primary side.An isolation transformer has the same number of windings on the primary as the secondary.The ratio of the windings is proportional to the increase or decrease in the secondary voltage. For example, twice the windings doubles the voltage and 1/2 the windings halves the secondary voltage. The isolation transformer is denoted as 1:1 and has the same voltage on the secondary as the primary.The ratio of secondary turns to primary turns is the same as the ratio of secondary voltage to primary voltage.e.g. if the secondary to primary turns ratio is 1/10, then the secondary voltage will be one tenth of the primary voltage.


How much is the secondry voltage vs with a primary voltage is vp equals 120v?

As far as a transformer is concerned, the secondary voltage Vs value cannot be determined by the primary voltage Vp alone. For the simplest of calculations the transformer primary-secondary turn ratio must be known. For an ideal transformer ( and practicaly ideal transformers don't exist as there will be various losses in the transformer cores and windings), the simple equation relating secondary voltage to primary voltage would be : Vs/Vp=Ns/Np=Ip/Is where Ns is the number of winding turns in the secondary of the transformer, and Np the primary. Ip is the primary current and Is the secondary.


HOW do I SELECT A STEP DOWN TRANSFORMER?

By looking to the number of turns in the Primary and Secondary Coils. "A Step down transformers are designed to reduce electrical voltage. Their primary voltage is greater than their secondary voltage. This kind of transformer "steps down" the voltage applied to it."


Difference between input and output transformer?

The 'input' side of a transformer is called its 'primary' side, whereas the 'output' side is termed its 'secondary' side. The ratio of its secondary to primary voltage is equal to the ratio of the number of turns in the secondary windings to the number of turns in the primary winding. So if, for example, a transformer's secondary winding has twice as many turns as its primary winding, then the secondary winding will produce twice the voltage applied to the primary winding.


How can you identify which one is step up or step down transformer?

A transformer has two windings, termed the 'primary winding' and the 'secondary winding'. The primary winding is the winding connected to the supply, while the secondary winding is connected to the load. The secondary voltage of a 'step up' transformer is higher than the primary voltage; the secondary voltage of a 'step down' transformer is lower than the primary voltage. The simplest way to determine whether a transformer is a step up or step down, is to measure the primary and secondary voltages. If you are simply looking at a transformer, then the transformer's insulated bushings will give you a clue -the higher voltage bushings are much bigger than the lower voltage bushings. If you have access to the inside of the transformer, then the higher voltage windings are thinner and have a greater number of turns than the lower-voltage winding.


What is high voltage side?

You are probably describing a transformer. The 'high voltage side' of a transformer is the winding with the greatest number of terms. It could be the primary or the secondary winding.


Summary of the step-down transformer?

A step- down transformer is one whose secondary voltage is less than its primary voltage, it is used to reduce 'step down' the voltage applied to it. The number of coils in the primary circuit is greater that the secondary circuit. For instance, to step down 480 Voltage to 240 voltage, you need a step down transformer whose ratio of primary coils to secondary coils is 2:1.


What is the definition of transformation ratio?

The turns ratio of a transformer is the number of primary turns to secondary turns. This defines how the transformer will change the voltage and current. For N1 primary turns, and N2 secondary turns, N1/N2 will be the turns ratio; the secondary voltage will be:the primary voltage x (N2/N1); The secondary current will be:primary current x (N1/N2)


Are number of turns on primary side and secondary side same in case of star star connections?

The number of primary and secondary turns, or turns ratio, determine the secondary voltage given a particular primary voltage. So, for instance, if the primary voltage is 480/277 wye, and the desired secondary voltage is 208/120 wye, the turns ratio would be 2.3:1. If the primary and secondary voltages are the same, then yes, the number of turns on primary and secondary would be the same. But if you're not converting delta to wye or vice-versa, why would you have a transformer with the same input and output voltage, other than an isolation transformer?


How do you work out the secondary voltage in a transformer?

The voltage ratio is the same as the turns ratio for an ideal transformer, and most transformers are close to being ideal. So use the following equation:Vs/Vp = Ns/Np


How do you find the secondary to primary transformer voltage ratio?

Turns Ratio = (Primary turns / Secondary turns) To calculate the turns ratio you have to actually know the number of turns or wraps on the primary and secondary coils. Nobody knows that usually the manufacture of the transformer doesn't even know. So what you can use as and equivalent is to calculate the voltage ratio. So what you typically need to look for is the Input voltage and divid it by the output volatge. Usually that would be as follows; (Primary Voltage/Secondary Voltage) = Voltage Ratio


What changes a low voltage into a higher voltage?

The step up transformer is used to change the voltage from high to low or low to high voltage by eitherincreasing the number of inding or reducing the number of winding in the transformer,thus when the winding reduced on side of primary winding and ingreasing number of winding on secondary side it means the transformer should be step up transfo0rmer,and when the you increase number of turnsin primary side and reduce turned on secondary sidde the transformer said to be step down transformer