answersLogoWhite

0


Best Answer

The plate heat exchanger is used in multiple systems in the field of HVAC, including geothermal water heating systems, instantaneous domestic hot water systems, semi-instantaneous domestic hot water systems, swimming pool constant temperature maintenance systems, solar hot water systems, etc.

Plate heat exchanger systems provide plate heat exchanger designs for each application:

1. Geothermal water heating system: The heat exchanger acts as a separate device for the host of the heat pump and the open cold and heat source, which overcomes the corrosion of sensitive equipment such as the host by water quality.

2. Domestic hot water system: The good heat transfer performance makes the plate heat exchanger gradually replace the traditional container heating system, with a smaller area and more economical investment.

Instantaneous domestic hot water system-to ensure that users have hot water supply anytime, anywhere, compact system, no storage tank required, large boiler capacity required, large heat exchanger Semi-instantaneous domestic hot water system—requires smaller boiler capacity, smaller heat exchanger, easy to grow bacteria in the storage tank, and requires additional places for the storage tank.

3. Swimming pool constant temperature maintenance system: Install a heat exchanger to make the pool water circulate independently. In order to avoid the corrosion of the plate by the chloride ion in the pool water, please choose the plate material carefully.

4. Solar hot water system: As one of the clean energy sources, solar energy has attracted more and more attention. By using a heat exchanger, the loop for collecting solar energy and the loop for domestic hot water can be separated, thereby effectively protecting it. Cleanliness of the domestic hot water loop.

If you want to know more, you can search:YOJO

User Avatar

Fang Mia

Lvl 5
3y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Application of plate heat exchanger
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Chemical Engineering

Why Expansion bellows are required in heat exchanger?

expension belows are used for heat exchanger to avoid thermal stress


What is a gas furnace heat exchanger?

The heat exchanger is the metal wall or tubing that is heated up when the burners are ignited. The inside of the heat exchanger allows the toxic flue gases produced from the burners to exhaust out through the furnace flue. The outside of the heat exchanger is where the cold air passes over, becomes warmed, and is blown throughout the ductwork of the home. The heat exchanger is the only wall separating the toxic flue gases from the supply air. If a crack develops in the heat exchanger, there is a potential for carbon monoxide gas to leak over to the supply side and be blown throughout your rooms. Carbon monoxide gas is odorless. The human senses will not detect its presence. Ron Ferrara- DHR Mechanical Services, Inc.


Heat Exchanger Types and Uses?

heat sink classified according to the shape, the shape is how to dissipate within the selected heat sink that is the main intension here,, k type l type rectangular triangular chassis i know this much u can down load the pdfs for the types how to select the required heat sink 9844354439


What is the purpose of floating head in heat exchanger?

allow for tube expansion


How hot does a gas fired heat exchanger get?

There are specific values for heat rise across a furnace heat exchanger given in all installation/operation manuals for all furnaces. As long as these limits are adhered to by the installer the heat exchanger will not overheat. I know this does not answer the question but there is no one blanket answer for all furnaces. Basically the more airflow through the furnace, the lower the HX temp and to determine when the airflow is correct a heat rise test is done and the airflow is set to the mid point of that specification.

Related questions

Where is the dollar plate on a heat exchanger?

It's the flat, flanged cover on the front (and sometimes the rear) of a shell & tube heat exchanger.


What is plate heat exchangers?

a plate heat exchanger is a metal plate which is will be in contact with another item eg air or another metal object to move heat from one to another


How to solve the failure of plate heat exchanger?

The plate heat exchanger has the characteristics of high heat transfer coefficient, small pressure drop, compact structure, light weight, small footprint, convenient area and process combination, strong versatility of parts, wide selection of materials, and simple completion of large-scale production. Widely used in the fields of food, machinery, metallurgy, petrochemicals and ships.In order to ensure the normal operation of the plate heat exchanger, it is particularly important to extend the service life of the plate heat exchanger components (such as plates and rubber pads), and to understand the problems and the causes of the plate heat exchanger and the treatment methods.Brazed Plate Heat ExchangerBrazed Plate Heat Exchanger Model ZL20BProblem:The plate heat exchanger has leakage (small amount, water droplets are not continuous) and leakage (large amount, water droplets are continuous). The primary parts of external leakage are the seal between the plate and the plate, the position where the plate seals the leakage groove, and the inner side of the end plate and the compression plate.The reason:The clamping scale is not in place, the scale across the ground is not uniform (the ground scale error should not be greater than 3 mm), or the clamping bolt is loose. Part of the gasket is separated from the sealing groove, the main sealing surface of the gasket is dirty, the gasket is damaged or the gasket is aging. The plate is deformed, and the misalignment causes the running mat.Solution:In the state of no pressure, clamp the equipment from the beginning according to the clamping scale supplied by the manufacturer. The scale should be uniform and common. The error of the compression scale should not exceed ± 0.2N (mm) (N. is the total number of plates) The parallelism should be kept within 2 mm. Make a symbol on the leakage part, and then check the heat exchangers one by one, and install or replace the gaskets and plates from scratch.YOJO can provide a variety of heat exchange equipment solutions for the failure of the plate heat exchanger. For leakage problems of the plate heat exchanger, if there are other questions, please contact YOJO.Tag: Heat exchange equipment solution, Heat exchange equipment, plate heat exchanger leakage


What is a plate heat exchanger used for?

Plate heat exchangers are used in combination boilers, also sometimes referred to a 'combi-boilers'. The plate heat exchanger is found inside the hot water section and uses metal plates to move heat between two fluids.


How do you clean welded plate heat exchanger?

Refluxing solvent is one way but an ultrasonic batch is better.


Is it correct that Plate Type Heat Exchangers can only handle very clean liquids practically free from any suspended particles as compared to Shell and Tube type Heat Exchanger?

It really depends on the fluid. If the fuild is taken into consideration when sizing the heat exchanger then there are times when a plate and frame can work. It really comes down to proper sizing.


Function of heat exchanger?

There are actually many types of plate heat exchangers, and the YOJO brand has introduced brazed plate heat exchangers and gasket plate heat exchangers. Today is the home of brazed heat exchangers.Brazed plate heat exchangers have no headers, tie rods or sealing gaskets, and the plates are brazed at a temperature of 1100 ° C. During the assembly stage, a piece of brazing material (usually copper, and nickel) is placed between the two plates, the package is compressed, and then baked for several hour.BPHE is more compact and lighter, and the brazing material has the functions of both washer and frame. The intersection between the corrugations of the two coupling plates forms a dense network of contact points, which impart pressure tightness and generate vortex flow, thereby improving heat exchange. In this way, even at low nominal input speeds, the turbulence of the fluid is high, and for low flow rates, the fluid flows from laminar to turbulent.


Heat exchanger for ammonia absorption refrigeration system?

there are two type of heat exchanger in absorption refrigeration, first is liquid heat exchanger and other is gas heat exchanger.both heat exchanger function is same, to transfer heat (hot medium to cold medium) without violate second newton law of thermodynamics. liquids heat exchanger is between boiler and absorber vessel mean while gas heat exchanger between evaporator and absorber.


What does a feed pump do in pasteurization of milk?

The feed pump promote the flow of raw milk from balance tank to plate heat exchanger.


How do you calculate the water flow requirements of a plate heat exchanger?

"http://wiki.answers.com/Q/How_do_you_calculate_the_water_flow_requirements_of_a_plate_heat_exchanger" "http://wiki.answers.com/Q/How_do_you_calculate_the_water_flow_requirements_of_a_plate_heat_exchanger"


Exchanger is not transfer heat why?

Heat exchanger manufacturers is an ISO 9001 certified company located in Coimbatore, Tamilnadu. The company started its functioning 2011 in, with a strong background in heat exchanger manufacturing. Our well-experienced and dedicated employees consistently thrive to serve our customers with the best heat exchanger solution. visit :: heatexchangersmanufacturers.in


What is heat exchanger duty?

The duty of a heat exchanger can be defined in an easy way as "The amount of heat exchanged from a fluid at a higher temperature to the fluid at lower temperature in unit time by a heat exchanger is called its duty"