Related Questions

How can you calculate the copper bus bar according to the amp?

To obtain the amp of the copper bus bar, multiply the width of the bus bar by the thickness of the bus bar to obtain the current carrying capacity of the bus bar.


What is the bus bar size for 6000A?

5-6x150 Cu. BUS BAR PER PHASE


What are the types of bus bar arrangements?

Single bus is used in smaller, less important substations. A fault on the bus requires tripping of all lines into the bus. When higher redundancy is necessary, ring and breaker and 1/2 schemes are used. These are the three most common.


What does the term 'bus bar' refer to?

The term "bus bar" refers to a strip of bar of brass, aluminum, or copper. This strip of bar conducts electricity with a distribution and switch board.


How do you convert bus bar to amp?

Bus bar is a physical component that carries the current. AMP is unit of current. They can not be converted


Why the impedance of infinite bus bar is zero?

...because it is an infinite bus bar, meaning it can supply infinite current. By Ohm's law, since the voltage at the bus bar is fixed, to have infinite current, you must have a zero impedance.


Difference between bus bar and bus duct?

Bus bars are actually simple conductor strips of copper using for connection between one system to another.for example transformer to panel. bus ducts are enclouser of that bus bar


What is the difference between a 200 amp bus bar and a 150 amp bus bar?

The primary difference between a 200 amp bus bar and a 150 amp bus bar lies in their current-carrying capacity. A 200 amp bus bar can safely handle a maximum load of 200 amps, making it suitable for larger electrical systems, while a 150 amp bus bar is limited to 150 amps. This difference affects their applications; a 200 amp bus bar is typically used in larger service panels or commercial settings, whereas a 150 amp bus bar may be adequate for smaller residential systems. Additionally, the physical size and material specifications may vary to accommodate the different current ratings.


What are the conditions for Synchronization of three phase alternator and bus bar?

voltage of incoming machine should be same as that of bus bar voltage


Bus bar and bus duct sizing calculations?

busbar sizing & calculation


What is difference between bus tie and bus coupler?

Bus coupler is use to separate the main bus and reserve bus bar while the bus tie is used for paralleling and syncronizing.


How do you calculate bus bar size?

You just Calculate Size of Bus bar which has been mentioned below:Example: Calculate Size of Bus bar having Following DetailsBus bar Current Details:Rated Voltage = 415V,50Hz ,Desire Maximum Current Rating of Bus bar =630Amp.Fault Current (Isc)= 50KA ,Fault Duration (t) =1sec.Bus bar Temperature details:Operating Temperature of Bus bar (θ)=85°C.Final Temperature of Bus bar during Fault(θ1)=185°C.Temperature rise of Bus Bar Bar during Fault (θt=θ1-θ)=100°C.Ambient Temperature (θn) =50°C.Maximum Bus Bar Temperature Rise=55°C.Enclosure Details:Installation of Panel= Indoors (well Ventilated)Altitude of Panel Installation on Site= 2000 MeterPanel Length= 1200 mm ,Panel width= 600 mm, Panel Height= 2400 mmBus bar Details:Bus bar Material= CopperBus bar Strip Arrangements= VerticalCurrent Density of Bus Bar Material=1.6Temperature Co efficient of Material Resistance at 20°c(α20)= 0.00403Material Constant(K)= 1.166Bus bar Material Permissible Strength=1200 kg/cm2Bus bar Insulating Material= BareBus bar Position= Edge-mounted barsBus bar Installation Media= Non-ventilated ductingBus bar Artificial Ventilation Scheme= without artificial ventilationBus bar Size Details:Bus bar Width(e)= 75 mmBus bar Thickness(s)= 10 mmNumber of Bus Bar per Phase(n)= 2 NoBus bar Length per Phase(a)= 500 mmDistance between Two Bus Strip per Phase(e)= 75 mmBus bar Phase Spacing (p)= 400 mmTotal No of Circuit= 3 No.Bus bar Support Insulator Detail:Distance between insulators on Same Phase(l)= 500 mmInsulator Height (H)= 100 mmDistance from the head of the insulator to the bus bar center of gravity (h)= 5 mmPermissible Strength of Insulator (F')=1000 Kg/cm2