what do you mean by 50 KA for 1 sec
Lt cables has own impedance which reduce the short circuit fault level
Unit of fault level is KA. Kilo amps
This describes what is known as the 'fault level' at a particular point in an electricity transmission or distribution system, expressed in megavolt amperes, enabling the theoretical value of fault current to be calculated at that point in the system, in order to ensure that the relevant switchgear is capable of interrupting that level of fault current.
tiltmeter
The calculation of greatest fault current of system is required for calculation of the capacity of the switchgear or bus bar or cable. The source of the supply will be the consideration.The MVA/kVA capacity of the transformer or generator which is the source. The simple equation to find the short circuit current is 1.1 x V L I = --------------- Amps √ 3 x Z I - short circuit current Line voltage is multiplied by 1.1 to take care of 10% rise in voltage Z Impedance in ohms % Z x10 x kV 2 Z = --------------------- kVA Detailed calculation method is available in www. ecmweb.com You must read it if you are really interested to learn the subject. There are so much reading material on the subject in the net itself Similarly read this link http://books.google.co.in/books?id=yiT9Doq8TRwC&pg=PA184&lpg=PA184&dq=short+circuit+calculation+of+bus+bar+&source=web&ots=L1ww-bULxl&sig=Ker1LfRB8E9pWC5-fKnyNqPi_K0&hl=en#PPA184,M1
In the event of a busbar fault, the next level of protection will operate and disconnect the busbars.
Lt cables has own impedance which reduce the short circuit fault level
How to find out the calculation for dry calibration of a level instrument used on the top of the tank? How to calibrate level instrument with the help of weights?
boiler drum diffferential pressure level calculation explained
Unit of fault level is KA. Kilo amps
Steam Rate calculation Formula for Steam Turbine
The operator was at fault for not detecting that an RPV level gauge was malfunctioning. The operator and the state was at fault for not having an emergency plan.
This describes what is known as the 'fault level' at a particular point in an electricity transmission or distribution system, expressed in megavolt amperes, enabling the theoretical value of fault current to be calculated at that point in the system, in order to ensure that the relevant switchgear is capable of interrupting that level of fault current.
RAID 1 is the most fault tolerant, as all drives have to fail to lose data.
Do you mean combat level? - the number other players see when hovering their mouse pointer over your character?If so, your combat level is calculated from the following skills.Attack and Strength or Ranged or MagicDefenceConstitutionPrayerSummoningIf your highest combat related skills are in Melee (attack and strength) then that's what your combat level will be calculated from. If your Magic level became higher then the calculation for your combat level would include that. Likewise with ranged. Defence, Constitution, Prayer and Summoning(if a member) are included in whichever calculation applies.It's a bit complicated. Runescape Wiki's page on Combat Level (see link below) includes the formulas used for the calculation.
The coolant level sensor in the reservoir is probably at fault.
false