answersLogoWhite

0

Busbar fault level calculation

Updated: 10/18/2022
User Avatar

Wiki User

14y ago

Best Answer

what do you mean by 50 KA for 1 sec

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Busbar fault level calculation
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Why short circuit calculation is not required for LT cables?

Lt cables has own impedance which reduce the short circuit fault level


What is the unit substitution fault finding technique?

Unit of fault level is KA. Kilo amps


What do you mean by fault MVA?

This describes what is known as the 'fault level' at a particular point in an electricity transmission or distribution system, expressed in megavolt amperes, enabling the theoretical value of fault current to be calculated at that point in the system, in order to ensure that the relevant switchgear is capable of interrupting that level of fault current.


Which type of fault monitoring device is most like a carpenter's level?

tiltmeter


How is Fault level calculation computed?

The calculation of greatest fault current of system is required for calculation of the capacity of the switchgear or bus bar or cable. The source of the supply will be the consideration.The MVA/kVA capacity of the transformer or generator which is the source. The simple equation to find the short circuit current is 1.1 x V L I = --------------- Amps √ 3 x Z I - short circuit current Line voltage is multiplied by 1.1 to take care of 10% rise in voltage Z Impedance in ohms % Z x10 x kV 2 Z = --------------------- kVA Detailed calculation method is available in www. ecmweb.com You must read it if you are really interested to learn the subject. There are so much reading material on the subject in the net itself Similarly read this link http://books.google.co.in/books?id=yiT9Doq8TRwC&pg=PA184&lpg=PA184&dq=short+circuit+calculation+of+bus+bar+&source=web&ots=L1ww-bULxl&sig=Ker1LfRB8E9pWC5-fKnyNqPi_K0&hl=en#PPA184,M1

Related questions

What Happen if BUS BAR Protection relay fails?

In the event of a busbar fault, the next level of protection will operate and disconnect the busbars.


Why short circuit calculation is not required for LT cables?

Lt cables has own impedance which reduce the short circuit fault level


What is the calculation for the calibration of a Level instrument displacement type dry method?

How to find out the calculation for dry calibration of a level instrument used on the top of the tank? How to calibrate level instrument with the help of weights?


How calculate actual boiler drum level?

boiler drum diffferential pressure level calculation explained


What is the unit substitution fault finding technique?

Unit of fault level is KA. Kilo amps


How do you measure level of tank?

Steam Rate calculation Formula for Steam Turbine


Who was at fault Why three mile island?

The operator was at fault for not detecting that an RPV level gauge was malfunctioning. The operator and the state was at fault for not having an emergency plan.


What do you mean by fault MVA?

This describes what is known as the 'fault level' at a particular point in an electricity transmission or distribution system, expressed in megavolt amperes, enabling the theoretical value of fault current to be calculated at that point in the system, in order to ensure that the relevant switchgear is capable of interrupting that level of fault current.


What level of RAID is the most fault tolerant?

RAID 1 is the most fault tolerant, as all drives have to fail to lose data.


Does mage level up your account in runescape?

Do you mean combat level? - the number other players see when hovering their mouse pointer over your character?If so, your combat level is calculated from the following skills.Attack and Strength or Ranged or MagicDefenceConstitutionPrayerSummoningIf your highest combat related skills are in Melee (attack and strength) then that's what your combat level will be calculated from. If your Magic level became higher then the calculation for your combat level would include that. Likewise with ranged. Defence, Constitution, Prayer and Summoning(if a member) are included in whichever calculation applies.It's a bit complicated. Runescape Wiki's page on Combat Level (see link below) includes the formulas used for the calculation.


Coolant light stays on?

The coolant level sensor in the reservoir is probably at fault.


Doe RAID 1 provides a high level of fault tolerance?

false