No!

The 32 amp rating is slightly more than the circuit that supplies it can handle in continuous power supplied, therefore if you replace it with a socket that has a smaller amperage rating (16) you will have the potential to draw through the new socket more (32) amps than it was rated for and thus have a component failure and possible electrocution hazard. The 16 amp socket will physically work but you and anyone who will use the generator in the future MUST ensure that no more than 16 amps are drawn through the socket . I recommend that a like in kind replacement , 32 amps for 32 amps so the full 32 amp supply can be used safely. my opinion.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you change the 32amp 240v socket to a 16amp socket on your generator?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering
Related questions

What size breaker for 8kw 277volt heater?

32amp 30ma rcbo


Can a step down transformers be used to convert 240v 32amp to 120v 32amp?

Yes, the capacity of the transformer, on the primary side, to handle 240 volts x 32 amps is 7680 VA. This will allow on the secondary side an output of, I = W/E, 7680/120 = 64 amps, well within the range you are looking for.


What is 32 amp in kw?

It depends on the voltage. A load of 32 amps at 120 volts will be 3.84 kW. A load of 32 amps at 240 volts will be 7.68 kW. For any other voltage, multiply the voltage by 0.032. All these calculations assume a resistive (non-reactive) load.


Would there be any problems powering on a 16 amp single phase device from a 32 amp three phase circuit?

if it is connected correctly it will run. However, you may want to modify the circuit to confirm to the NEC so you may protect the device from overloading and burring up!for example you may use the 32Amp circuit as a sub-panel!


Do i need a double pole switch for my 7200w hob and can i wire into my 32amp ring main?

A hob will have to be on it's own circuit, usually a radial fed from the consumer unit. The reason for this is when you work out your amperage 7200 Watt divided by 230 Volts this gives you 31 Amp which is why you can't wire it into your existing ring main. With other appliances switched on it would keep tripping the protective breaker at the consumer unit.


How many watts can you use with a 32amp mcb?

To answer this question a voltage must be stated. W = Amps x Volts.Assuming that you keep a tidy house, your power factor is always 1 ,and you derate your circuit breakers 10% for safety . . .If in a 120v circuit . . . P120 = 0.9 x 120 x 32 = 3,456 wattsIf in a 240v circuit . . . P240 = 0.9 x 240 x 32 = 2 x P120 = 6,912 watts


How many amps in normal household sockets?

Typically either 15 A or 20 A. You can be sure by checking the breaker value in the electric panel that controls the outlet. If it were a 20 A breaker then the total amps for all outlets on the breaker would be 20A. usually you don't want to exceed 80% of rated current so in reality for a 20 A breaker you would have a 16 A capacity.


What are 3 type of electrical circuit?

Lighting CircuitsRadial CircuitsRing circuitsRing CircuitsA ring circuit can serve an area up to 110 square metres (120 square yards), 2.5mm2 cable is used to wire the circuit and the circuit has a 30amp fuse or 32amp MCB on the consumer unit. It is usual for a house to have one ring circuit upstairs and one ring circuit downstairs.Ring circuits can have extra sockets added to them by adding a 'spur' onto a ring circuit. A spur is a branch off the ring circuit, usually from an existing circuit, although a junction box could also be used. Theoretically as many spurs as sockets could be added, but the maximum load of the circuit (30/32amp) still exists).Radial CircuitsRadial circuits can therefore only serve a smaller area. Using 2.5mm2 cable combined with a 20amp fuse/MCB an area of 20 square metres (24 square yards) is permissible. For 4mm2 cable combined with a 32amp MCB or a 30amp cartridge fuse (a re-wirable fuse is not allowed) an area of 50 square metres (60 square yards) is permissible.In a similar way to ring circuits spurs can be added at points along the radial circuit if required. High powered appliances (cookers / showers) must have their own radial circuit.Lighting CircuitsLighting circuits are basically radial circuits. There are two distinct types of lighting, circuit the loop-in circuit and the older junction box circuit. Most houses combine aspects of both types of circuits. The loop-in circuit has a cable, running from light to light terminating at the last light as in the conventional radial circuits and then single cable run from the lights to the light switches.The other type of lighting circuit has a junction box for each light. The cable runs from the consumer unit to the first junction box and then onto the next terminating at the last junction box. Then another cable is run from each junction box to its light and another wire from the junction box to that light switch. The cable used for a lighting circuit is 1mm2 or 1.5mm2 for long runs.Another AnswerI think that this question is referring to more fundamental circuits than those described above. There are fourcategories of circuit: series circuits, parallel circuits, a combination of the two (series-parallel circuits), and complex circuits. Complex circuits describe circuits which don't fall into the first three categories.