No, the six outlets are not amperage rated to be connected to a 20 amp circuit. A normal 15 amp receptacle can not be protected by a 20 amp breaker. Change the 20 amp breaker to a 15 amp breaker. This combination will pass code regulations.
===============
In the United States, in a home, you can connect two hard-wired (not cord and plug connected) fans and six receptacles (outlets) to a single 20 amp circuit provided the 2 fans do not draw more than 10 amps together. If they are cord and plug connected, this limitation on the fans does not apply.
In commercial and industrial installations, power to hard-wired equipment is provided on different circuits than receptacles.
no
Technically, they can be on a 15 amp breaker when you use 15 amp outlets. There is a difference. Be sure to check your local code (just call the city building department and tell them you have a code question). some cities require the bedroom outlets to be on an arc-fault breaker.
It is unusual to have multiple outlets on a 30 Amp service. If you do this you need outlets rated at 30 amps and 10 AWG wire.
A 15 amp breaker protecting # 14 wire.
No. The breaker must protect the circuit components such as wiring, outlets and switches that are connected to the breaker. Therefore if you have a 30 amp circuit as dictated by its components you need to protect it with a 30 amp or less breaker.
no
Technically, they can be on a 15 amp breaker when you use 15 amp outlets. There is a difference. Be sure to check your local code (just call the city building department and tell them you have a code question). some cities require the bedroom outlets to be on an arc-fault breaker.
It depends on the use of the 10 outlets. 20 amp is the norm. If this is in a shop with heavy loads then you would have to break them up.
A 30 amp breaker is usually used for a dedicated 30 amp device. Ordinary 15 amp receptacles can not be connected to a breaker of higher trip capacity than the rating of the receptacle. The wire size for a 30 amp breaker is #10 AWG.
It is unusual to have multiple outlets on a 30 Amp service. If you do this you need outlets rated at 30 amps and 10 AWG wire.
A 15 amp breaker protecting # 14 wire.
If you never plug anything into them, there is no limit. If the total current drawn from all outlets exceeds 20 amps, the breaker will trip.
Use 15 amp breaker with 14 gage wire or 20 amp breaker with 12 gage wire. Either way will work just fine.
No, you need a 30 amp breaker (whether that's from a generator or not it doesn't matter) with the proper voltage.
As many as you want. It is the power consumed by the thing(s) plugged in that is of concern.
Two 20 Amp circuits with the outlets staggered so a different circuit is on two adjacent outlets. Should be GFCI protected.
Use a 15 amp breaker and 14 AWG wire and all switches and outlets rated at 15 amps or greater.