Best Answer

Yes, as long as it remains accessible and visible if you're in the attic (not buried in insulation). Don't forget the blank cover on the box.

User Avatar

Wiki User

โˆ™ 14y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

โˆ™ 6mo ago

Yes, it is possible to install a junction box in an attic. However, it is important to ensure that the installation meets local electrical codes and that the junction box is accessible for maintenance and inspections. It is recommended to consult a licensed electrician for proper installation.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you put a junctiOn box in an attic?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What are the rules for installing a junction box in the attic?

A 4"x 4" metal junction box w/ cover should do the trick. Just make sure you install box connectors to secure the cables where the cables enter the box. Also make sure that the box is "readily accessible" make sure the box won't be permanently concealed by sheet rock or other construction. Readily accessible in an attic space means from the top of the ceiling joists to the bottom of the roof rafters is to be no less that three feet.


How do you extend romex wire you moved an outlet you need to extend and connect?

You need to splice the extension Romex, using wire nuts, inside a covered junction box made for the purpose. If you can do it within the original outlet box you can put a blank cover on the box. If not you may have to install a new "old work" box in wall. If you can get to wire in attic or basement you could put the junction box in one of those locations. The junction box must be accessible so you can't bury it in the wall.


Are junction boxes normally used in wiring the first floor of a house?

The area of a home has nothing to do with wear a junction box is placed. A junction box is placed wear a junction box is needed to split a circuit. any splice SHALL be in a junction box a junction box SHALL be accessable


Can a 240V wire be run from the junction box and not the service box?

Junction box for what? Do you mean a sub panel?


In what situations does a junction box need to be weatherproof?

A junction box needs to be weatherproof if it is located outside. These junction boxes always need to be weatherproof since they are constantly exposed to rain and the elements.

Related questions

What are the rules for installing a junction box in the attic?

A 4"x 4" metal junction box w/ cover should do the trick. Just make sure you install box connectors to secure the cables where the cables enter the box. Also make sure that the box is "readily accessible" make sure the box won't be permanently concealed by sheet rock or other construction. Readily accessible in an attic space means from the top of the ceiling joists to the bottom of the roof rafters is to be no less that three feet.


How do you extend romex wire you moved an outlet you need to extend and connect?

You need to splice the extension Romex, using wire nuts, inside a covered junction box made for the purpose. If you can do it within the original outlet box you can put a blank cover on the box. If not you may have to install a new "old work" box in wall. If you can get to wire in attic or basement you could put the junction box in one of those locations. The junction box must be accessible so you can't bury it in the wall.


Is it ok to use plastic junction boxes in the attic Thanks?

Yes, Plastic junction boxes can be used in the attic of a home. They must be secured and have a cover on them. They must be accessable.


Can porcelain dolls be stored in the attic?

It could be stored in the attic but put it in a box or a container so the dust won't cover the doll


Are junction boxes usually wired in the first floor?

Junction boxes are usually laid out so that the circuit splices are located in the basement and in the attic. Attic junction boxes have to have a vertical clearance of three feet above it to make it legal.


Are junction boxes normally used in wiring the first floor of a house?

The area of a home has nothing to do with wear a junction box is placed. A junction box is placed wear a junction box is needed to split a circuit. any splice SHALL be in a junction box a junction box SHALL be accessable


Can you run a 240v wire from the electrical panel then put a junction box to run it where you want?

A 240 volt wire is the insulation factor of the wire. If you mean a 240 supply source from a distribution panel to a junction box then the answer is yes. You have to keep in mind that the box has to be accessible, meaning that you can get to the box to check the splice within the box. Don't bury the junction box behind the wall board.


Can a 240V wire be run from the junction box and not the service box?

Junction box for what? Do you mean a sub panel?


How far from a junction box must emt conduit be strapped?

I always put the first EMT clip/strap 1 foot or 12 inches away from the junction box, then every 5 feet or so after that.


Where is the smart junction box on a ford wind star?

03 windstar where is the smart junction box location


Do you need a junction box for each light fixture?

Can lights have a junction box attached to them. So yes.


How many 14 gauge electrical wires can you put in a 2x4 electrical box?

Answer varies. Is it a deep or shallow box? is there a receptical, a switch in the box as well? is it just a junction box? are they single wires or NM cable?