Yes this size motor can be operated by bringing a 600 volt three phase supply to it.
A single phase induction motor is mainly used in fans.It is capacitor start capacitor run induction motor.In three phase induction motor squirrel cage induction motor is mainly used in elevators,lifts,cranes.slip ring induction motor is mainly used in electrically driven ships.
The single phase induction motors are made self starting by providing an additional flux by some additional means. Now depending upon these additional means the single phase induction motors are classified as: 1.Split phase induction motor. 2.Capacitor start inductor motor. 3.Capacitor start capacitor run induction motor. 4. Shaded pole induction motor.
yes the motor will run but will draw more current and the torque will be not constant means not smooth due to unbalanced current
to start the motor and give more current to motor to run
A single-phase induction motor has a main winding and a starting winding. When the motor has run up to normal speed the starting winding can be switched out, but for small motors this is not usually worth the trouble.
A single-phase induction motor has a main winding and a starting winding. When the motor has run up to normal speed the starting winding can be switched out, but for small motors this is not usually worth the trouble.
This question doesn't really make any sense - any of the two phase? A three phase induction motor requires 3 phases to start - if a single phase is lost while the motor is already running then yes the motor will continue to run. A three phase motor will not start if it is missing a phase.
yes, It would run as long as the motor was not coupled to a load. Coupled to a load the motor would have no torque and would stall.
A single-phase induction motor has a main winding and a starting winding. When the motor has run up to normal speed the starting winding can be switched out, but for small motors this is not usually worth the trouble.
A single phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.
Synchronous motors run at synchronous speed. An induction motor that has the same number of poles must run at a sub-synchronous speed to create a second magnetic field (a field that is at a different phase angle) to generate torque.
zma da ghan mata sa razeEven if I do not understand the language used above I still believe that the answe above is very irrelevant, to say the least.Answer:1. Resistance start single phase motor2. Capacitor start single phase motor3. Capacitor start and run single phase motor4. Capacitor start capacitor run single phase motor