Can you properly change a 3-prong 240V outlet looks like standard plug but horizontal to the NEMA twistlock 20A style if they use a different number of wires extra ground neutral on a twistlock type?

No. You can't replace a 220V outlet with a 110/220V outlet without running the requisite neutral wire. If you do you will blow out any device that expects the neutral line to be connected.


How do you change from 15 amp fuse to 20 amp fuse?

The only way you can change a 15 amp to a 20 is you have to replace the 14 gauge wire going to it with a 12 gauge wire, then replace the 15 amp breaker with a 20 amp breaker. You can put a 15 amp outlet on a 20 amp circuit as long as there is more then one receptacle. A double receptacle counts as two receptacles. Steve Green Coeur d'Alene, Idaho


How do you wire a 6-20R outlet?

A 6-20R is 220V, 15/20A correct? If the outlet is within 75ft of the panel you need to run 12-2 to the outlet from the panel. I would recommend 12-3 as you can then upgrade to a 120/240V outlet later and you are not using a white wire as a hot. If you do use 12-2 wrap the white wire with electrical tape to show it's not neutral. Then just wire the outlet as a normal 220V outlet to a 20A 220V breaker.


Do you need a neutral when running a BLK Red and ground from a panel directly to a 240V 4800W 20A heater outlet?

No. The black is 220, the red is 220, and the ground serves as the neutral. the last answer "no" is correct but the reason is not. the ground is still a ground. the red is 110v and the black is 110v. together they are 220v. the neutral or (common) is for a 110v return. for example a stove or a dryer will have 2 hots a common and a ground because they use 220v and 110v. 220v to power the heating elements and 110 for the controls, light bulbs or the outlet on a stove. A construction heater only uses 220v and only requires the two hots and the ground for safety.


20 amp switch in a 15 amp circuit?

It can be done although it is bad practice provided the load doesn't continuously require more that 15 A. You should then use a 15 A fuse to protect the switch. Actually a fuse or circuit breaker is only there to protect the wiring and device and nothing else, e.g., if you run 14AWG wire then you want to protect that with a 15A (or smaller) fuse or breaker. Similarly 12AWG wire should be protected by a 20A (or smaller) fuse or breaker. The receptacles will only accept devices rated for them, i.e., NEMA 5-15R is rated at 125V 15A. NEMA 5-20R is rated at 125V 20A... the 5-20R is commonly known as "T" rated as it will accept either NEMA 5-15P or 5-20P plugs. The 5 indicates that it is a 125V rated 2-pole, 3-wire grounding receptacle.. the 15 or 20 is it's current rating.