In dray expansion evaporator, the liquid refrigerant is generally fed by an expansion valve. the expansion valve controls the rate of flow of refrigerant to the evaporator. In the evaporator the liquid refrigerant is vaporized and superheated by the time it reaches to the end of evaporator. At inlet of the evaporator, the refrigerant is predominantly in the liquid form with a small amount of vapor formed as a result of flashing at the expansion valve. the liquid refrigerant passes through the evaporator, more and more refrigerant is vaporized by the load. according to the load, the liquid will come into evaporator and vaporize and reaches to superheat at the end of the evaporator. The inside of the evaporator is far from dry but wetted with liquid so named as dry expansion evaporator.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Dry expansion evaporator
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the difference between the dry or direct expansion type of evaporator to the Flooded type evaporator?

Evaporator is said to be flooded type if liquid refrigerant covers the entire heat transfer surface. This type of evaporator uses a float type of expansion valve. An evaporator is called dry type when a portion of the evaporator is used for superheating the refrigerant vapour after its evaporation.


What do flooded evaporators use what type of expansion device?

dry-type


What type of expansion device do flooded evaporators use?

dry-type


What is the expansion of dry conditions into moist areas next to deserts called?

Desertification


What happens to dry ice if it is set out at 45 degrees celsius?

It will explode due to a large Expansion of the particles


What is the dry mode on my air conditioner do?

Dry Mode is a function that will reduce the humidity in the room. In this mode, as the air passes through the air conditioner the humidity will condense on the evaporator so that the air comes out drier. Reducing the humidity makes you feel cooler and more comfortable. Dry mode uses less power than cool mode.


How do you dry N O-dimethylhydroxylamine hydrochloride?

The hydrochloride salts are very easy to absorb moisture, and they are generally sealed with parafilm. If large amount, you can dry the chemical N,O-dimethylhydroxylamine hydrochloridewith rotary evaporator, equipped with an oil pump. The chemical will will dry faster and evenly. If small amount, just use an oil pump at at room temperature.


Why do you think the sublimation of dry ice and expansion of gases are not chemical reactions?

Because they are changes of state - physical changes - VERY easily reversed.


What are the names of the inventions made during the westward expansion?

railroads barbed wire dry farming steel plow windmills sod house


Can you keep a R-22 evaporator unit and replace the R-22 condenser unit to a R410a unit by changing the TXV and flushing out the lines with dry nitrogen?

Highly not recommended. If you found a contractor who would actually do this, run don`t walk away from that guy.


Why would You have water dripping out of out central air unit?

This is water that has condensed out of the room air on the evaporator coils of the air conditioner, and it is completely normal. If the humidity is high, one will see more water condensing and dripping from the air conditioner than when the room air is dry.


Why is the sublimation of dry ice and the expansion of gases not chemical reations?

A chemical reaction is one that changes the chemical properties of a substance. Sublimation is just going from solid to a gas and is only a change of state.