ethernet frame required minimum of 64 bytes expalin why?

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Ethernet frame required minimum of 64 bytes why?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Computer Science

What is the minimum and maximum size of an Ethernet frame?

The minimum size of an Ethernet frame is 64 bytes. Even if the VLAN tag is 4 bytes, the Ethernet frame with VLAN tagging remains 64 bytes.


What are the Ethernet frame parts?

what are the ethernet frame parts The source and destination MAC addresses


How many bytes is the data frame made by FCS and the header together?

14 bytes for the header and 4 bytes for the FCS (Frame Check Sequence) for a total of 18 bytes.


What information is not included in a Ethernet frame?

Frame Size


An Ethernet MAC sublayer receives 1510 bytes of data from LLC layer can data be ccencapsulated in one farme?

maximum data size in the Ethernet is 1500 bytes The data must split between two frames first frame must carry the maximum number of bytes 1500 second frame needs to carry only 10 bytes so: Data size for the first frame: 1500 bytes Data size for the second frame: 46 bytes with padding Answer in Arabic حجم البيانات القصوى في Ethernet القياسي هو 1500 بايت. البيانات من 1510 بايت، لذلك، يجب حدوث تقسيم بين إطارين. المعيار يفرض أن الإطار الأول يجب أن تحمل أقصى عدد ممكن من البايت اي (1500). الإطار الثاني بعد ذلك يحتاج فقط لنقل 10 بايت من البيانات؛ ومع ذلك فهو يتطلب حشوة لتصل إلى 46 بايت. وفيما يلي تفصيل يبين: حجم البيانات لالإطار الأول: 1500 بايت. حجم البيانات لالإطار الثاني: 46 بايت مع الحشو. Muatazz Falih. Basrah.

Related questions

What is the minimum and maximum size of an Ethernet frame?

The minimum size of an Ethernet frame is 64 bytes. Even if the VLAN tag is 4 bytes, the Ethernet frame with VLAN tagging remains 64 bytes.


What are the optical line coding methods?

Some common optical line coding methods include Non-return-to-zero (NRZ), Return-to-zero (RZ), Manchester encoding, Differential Manchester encoding, and amplitude-shift keying (ASK). These methods are used in optical communication systems to convert digital data into optical signals for transmission over optical fibers.


What is the maximum number of bytes that is allowed in a standard IEEE 802.3 Ethernet frame?

Totally depends on the hardware and software and their MTU (Maximum Transmission Unit). Usually MTU is set to 1500 bytes.


What is added when extra filler data is needed in a packet?

In Computer networking, you have data that is transmitted through packets. In which is what we call an Ethernet frame. That Ethernet frame broken up into several pieces. They are:The PreambleRecipient's MACSender MACTypeData (Your information)Pad (FILLER)FCSThe reason why we have the "Pad" is because your standard minimum for an Ethernet frame size is 64 bytes. However, it doesn't all have to be your actual data. For example, if you were to send data that was not 64 bytes. Your NIC (Network Interface Card) will automatically add extra data which is what we can the "Pad" portion. This adds data so that we are back up to the minimum value of 64 bytes within an Ethernet frame.


What is the purpose of padding in an Ethernet frame?

ensuring that the data portion of the frame totals at least 46 bytes


Why 64 bytes minimum in ieee 802.3?

FOR THE 802.3 FRAME CONTAINS Ethernet Header = 18 Bytes [Dst Mac(6) + Src Mac(6) + Length (2) +CRC(4)]Minimum Data Portion = 46 BytesMinimum Ethernet Frame Size = 64 Bytes Frames must be at least 64 bytes long, not including the preamble, so, if the data field is shorter than 46 bytes, it must be compensated by the Padfield. The reason for specifying a minimum length lies with the collision-detect mechanism. In CSMA/CD a station must never be allowed to believe it has transmitted a frame successfully if that frame has, in fact, experienced a collision. In the worst case it takes twice the maximum propagation delay across the network before a station can be sure that a transmission has been successful. If a station sends a really short frame, it may actually finish sending and release the Ether without realising that a collision has occurred. THATS WHY IT IS MINIMUM 64 BYTES


What are the minimum and max imum sizes for an Ethernet frame?

64 and 1518


The data portion of an ethernet frame may contain bytes of information?

46 to 1500


Which field of an Ethernet frame is used for error detection?

c) Check frame sequence. The FCS (4 bytes in length) field is used to detect errors in a frame


How many bits in the FCS in an Ethernet frame?

32 bits. which is 4 bytes (8 bits in each byte).


What protocols are in the Ethernet frame?

The ethernet frame carries the IP (Internet Protocol) The Ethernet frame is made up of the following: 7 BYTE PREAMBLE 1 Byte "Start OF Frame" delimiter 6 byte destination address 6 byte source address 2 byte length or type 46 - 1500 bytes variable 802.2 or ethernet header and data 4 byte Frame Check sequence


What is the example of packet switching network?

IP, Ethernet, Frame Relay, ...IP, Ethernet, Frame Relay, ...IP, Ethernet, Frame Relay, ...IP, Ethernet, Frame Relay, ...