full load torque is the torque which produces rated power at full speed
6.7 A
yes
The solution to this problem is to get the same size motor in HP at the correct voltage. This way the motor can correctly drive the connected full load without tripping the motor protection.
If the overload protection is set correctly to the motors full load amperage, any overloading of the motor will trip the protection and take the motor off line. Once the reason of the overload has been established and rectified, the overload protection is reset and the motor can be brought back on line.
FLA = full load amps <<>> It is a term that is associated with motors. It is the amperage of the motor when it operates at its full rated horsepower under load.
A breaker is based on the amperage that is drawn by the pump motor load. Find the full load amperage of the motor. The wire fed from the breaker has to be rated at 125% of the motors full load amperage. The breaker for motors have to be over sized, usually 250% of the motors full load amps.
As the load increases, the speed reduces to deliver the increased torque required.
The slip is proportional to the load torque in an induction motor. This can also be seen as a reduction in speed causing extra current to be induced in the rotor to supply the increased torque.
The 3-phase currents in the 3 coils of an induction motor will produce a steady rotating magnetic field.
The ratio is between 30% to 40 %
yes, It would run as long as the motor was not coupled to a load. Coupled to a load the motor would have no torque and would stall.
Squirrel Cage Induction Motor Disadvantages:Some of disadvantages or demerits of squirrel cage induction motors are listed below:Main disadvantage of squirrel cage induction motor is that they have poor starting torque and high starting currents. Starting torque will be in the order of 1.5 to 2 times the full load torque and starting current is as high as 5 to 9 times the full load current. In slip ring induction motors, higher starting torque can be attained by providing an external resistance in the rotor circuits during starting of the slip-ring induction motor. This arrangement in slip-ring induction motors also reduces the high inrush currents during starting of induction motor.Squirrel cage induction motors are more sensitive to the supply voltage fluctuations. When the supply voltage is reduced, induction motor draws more current. During voltage surges, increase in voltage saturates themagnetic components of the squirrel cage induction motor.Speed control is not possible in squirrel cage induction motor. This is one of the major diadvantages of squirrel cage induction motors.The total energy loss during starting of squirrel cage motor is more compared to slip ring motors. This point is significant if the application involves frequent starting
Friction is present at the motor shaft and also in various parts of the load. The friction torque is equivalent value of various friction torques referred to the motor shaft.
induction motors have very little starting torque as the motor come up to speed it reduces the torque load until it gets near synchronous speed
Same as what? at maximum speed and torque, the motor delivers maximum power.
yes
4 times
120 degrees