Best Answer

The trap and drain in most sinks gets it's venting from the overflow tube in the sink or in the case of a double kitchen sink, one side gets it from the other. One problem is with most cultured marble and cast sinks. Most of these do not have an overflow feature and may drain slow.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How Trap and the trap should be vented?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the best trap to use for plumbing?

A Vented Running trap with two clean outs or a P trap.


How do you install condensate p-trap?

The same as any other P trap except it should empty into a properly trapped and vented fixture


How come gas doesn't come back up in the toilet?

toilets have a built in water trap And they should be properly vented to prevent trap seal loss


Do you need an air vent installed for the dishwasher and garbage disposal and if so can it be installed another way if needed?

Your kitchen sink should already be vented if there is a p-trap draining to the wall. if it is an s-trap it is not vented and not to present code requirements. The dishwasher drain goes into the side of the disposal and the disposal should drain to the trap. A separate vent is not required for the disposal or dishwasher as the trap for the sink is what requires a vent.


What is the proper way to run a condensate drain with a trap Does it need a vent?

The condensate drain on the a-coil should have a trap and the trap should be vented for proper operation . The vent should rise above the top edge of the drain pan in the unit. Their should be a capped clean out before the vent.


Why is central air unit sucking the water from the a- coil down and dripping on the motor It shorted out your breakers and you replaced them The water drain is clear What is causing this hard vacuum?

The condensate drain on the a-coil should have a trap and the trap should be vented for proper operation .


What is a legal and commonly used trap bell trap S trap drum trap or P trap?

Which of the following is a legal and commonly used trap? bell trap S trap drum trap P trap


What is a legal and commonly used trap bell trap S trap drum trap P trap?

which of the following is a legal and commonly used trap? bell trap S trap drum trap or P trap


How do you stop a leak above a trap?

Steam trap? Grease trap? moisture trap (drip leg)? Running trap? "P" trap? Drum trap. 1/2 S trap? sediment trap?


Should the trap be before or after vent or condensation drain?

The trap should be before the vent. The trap is used to maintain a watter barrier to prevent waste water and sewer gasses from entering the home. The vent is use after the trap to allow the water to flow freely in the pipe with out drawing the water from the trap.


Should we trap animals?

I don't to act fat but trap them for food.Maybe a few a day.


Do you need to put a trap in your basement shower pan if you did not find any trap below the shower drain and the shower drain is directly connected to the sewer line by 2 foot pipe and T?

YES !!!!!!!! Minimum 2" P Trap Yes, and it needs a wye not a tee, and it needs to be vented properly.