I have 12 amps 208/3/60 what would the amps be @ 440/3
Because 3 phase voltage is not algebraic sum it is the vectorial sum. Vijaye Raj A.I.E.M.D
Not directly. You could use a 220V - 440V transformer to boost the voltage up to 440. Be sure its rated for the proper KW. Check the nameplate on the device for the KW rating. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS. If you do this work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicatorto insure the circuit is, in fact, de-energized.
240, single phase for houses208 3 phase for comerical property, can be single phase.480 volt for industrial property or 660 volts,all 60 HzUSA calls it single phase but there is actually 2 hot leads coming into the house with a natural and a ground.It is actually two 120 volt 'hots' which are 180° out of phase from each other. Voltage between either of these and ground will be 120 V. Voltage between the two hots is 240 volts. It is single phase because it is pulled off one of the phases from 3-phase, then a center tapped transformer gives the two 'opposite phases' (ground/neutral is off the center tap)In Vietnam we have 440 volts, 3 phase, 50 Hz on the poles.They bring in one hot wire and one ground. I call this single phase,It equals 220 volts in your house.
LT is Low Tension - it means Low voltage. generally up to 440 Volts system is known as low voltage system
The voltage for a potential relay will depend on the circuit that the relay is installed in. The relay can be made for low voltages (5v) to higher voltages (440.)
The single phase voltage in India is 230v when we check with the phase and the nutral single line
You didn't mention whether the voltages are single phase or three phase or whether it is a commercial machine or one used in the home. I am assuming that you are asking about a single phase washer. That being said yes, 208 volts can be stepped up to 440 volts. To have the washer converted would mean finding a 440 single phase motor with the identical frame type that would fit the same configuration that the 208 volt single phase motor now resides in. The control voltage for the internal controls would also have to be changed out to the new voltage. The transformer would cost as much as a new machine so that is out of the question. You might want to price out a new 440 volt machine, sell the old 208 machine and the money that you get for the old machine, apply it to the cost of the new machine.
You Don't. 440volt 3-phase is actually 480 volts, taking a single phase gives 277Volts single phase. To get single phase 440 you would use one leg of three phase 440/760 three phase power.
Let's get the terminology correct. A 'phase voltage' is measured across a phase, whereas a line voltage is measured between two lines. So there is no such thing as a 'phase to phase' voltage -it's a line to line voltage (hence the term 'line voltage').
Phase voltage is equal to the line to line voltage divided by root 3 or 1.732. So 440 L-L/1.732 = 254V. Your phase voltage is 254V.
In three-phase there are three live wires and a neutral. The voltage of a three-phase system is always quoted as the live-to-live voltage, and the voltage from one live wire to neutral is 57.7% of that. A 440 v 3-ph system has 254 volts between live and neutral. <<>> The question statement is not correct. Two legs from a three phase three wire 440 volt system will still be 440 but classed a single phase. On a three phase four wire system supply, the voltages will be determined by the following equation. 440/(square root of 3) 1.73 = 254 volts. The second single phase voltage attainable from this source connection is any one of the three phase legs to grounded neutral center point. This is known as a wye or star point connected voltage supply. To obtain a 220 volt single phase voltage, the three phase system would have to have a voltage of 220 x 1.73 = 380 volts.
Star 220 v and delta 400 i star 58 percent only voltage applied delta 400v appliedAnswerThese figures do not represent three-phase, four-wire, system voltages, because if the line voltage were to be 440 V, then the phase voltage would be 254 V; or, if the phase voltage were to be 220 V, then the line voltage would be 381 V.
It is 230V single phase and 440V in 3 phase system at 50 Hz.AnswerIf the single-phase voltage is 230 V, then the three-phase voltage must be 400 V, not 440 V. The line voltage is 1.732 times the phase voltage.
You can not change it. 440 volt is by design. However you run it with 220 single phase supply, but it would run far lower power.
A three phase four wire commercial distribution service will not give you 240 volts. The nearest voltage you can get is 208 volts. It is a wye connection which gives you 208 volts between the three legs and 120 volt between any of the three legs and ground. This ground point is the systems neutral point.
About one million circular mill. You need to up the voltage.
For information about three phase electrical services see the answers to the Related Questions shown below.