What is the type and size of cable gland or 2 core cable?

To answer this question the size of the cable or the amperage of the load is needed to calculate the correct wire size and connectors to fit the cable.


Could you Calculate cable size for 100 kw load?

To calculate the cable size for a 100 kW load, you would need to consider factors such as the voltage of the system, the type of cable insulation, the ambient temperature, and the installation method. The cable size is typically determined by the maximum current the cable will carry without overheating. Using the formula: Cable size (mm²) = (2 x L x I x R) / (√3 x V x cosΦ), where L is the cable length, I is the load current, R is the resistance of the cable, V is the voltage, and cosΦ is the power factor, you can calculate the appropriate cable size for the 100 kW load.


What is the cable size required for a 400 amp and 350 amp load?

350mcm


How do you calculate the requirement of cable size for a given load?

If you know the size of the load to be served, multiply it by 125% ( times 1.25) and choose a conductor that is rated for that ampacity or higher.


What is the cable size required for a 250 amp and 160 amp load?

For a 250 amp load, a cable size of at least 3/0 AWG (American Wire Gauge) or 70mm^2 is recommended. For a 160 amp load, a cable size of at least 1/0 AWG (American Wire Gauge) or 50mm^2 is recommended. It is important to consult local electrical codes and regulations to ensure compliance.


For 100kw which cable size is good and how to find out cable size?

100 kw is the power drawn by the load. to calculate the cable size you need to know the voltage. From that you can calculate the current. this decides the cable size. for example if the voltage is 400Volts then the current flowing in the circuit when the load is 100 KW will be 250 amps. (100,000/400). for 250 amps to flow with out causing excessive heating of the cable the cross sectional area of the copper cable should be 150 sq mm.for a round cross section the diameter will be roughly 15mm.


What is the cable size for a 1500 kVA generator with cable length of 50 meters?

35 KVA generator using for load 100 meter length which cable need to used


How do you decide cable size for required load?

i=v/R and R=rho.L/A . by analysing these fourmulas we find the size . here i is electric current in the conductor to flow or load current to flow . v is the voltage across the conductor , R is the resistance of the conductor . L is the length of the conductor ,rho is a constant of a material called specific resistance here the the material is the material of the conductor , A is the area of cross section of the conductor .


What is the correct cable size for the 550 KVAR capacitor bank?

Cable sizing is based on amperage of the load. The rating of the capacitor bank and the voltage at which it operated need to be stated to give an answer.


How thick is the cable to conduct 22.5 kw of power?

Cable doesn't conduct power, it conducts current. Either the voltage and load must be known or the amperage the cable will need to conduct to determine the size of the cable. Once the amperage is known, there are multiple tables online that have cable size and amperage. Do a Google search for "conductor amperage" for examples.


How do you calculate the cable size for a 115kw 3 phase induction motor 16 meter run for cable 415v?

take the full load current 1.732*415*I*0.85*efficiency=115*1000 => I? Depending on the value of the full load current and designed and ambient temperatures of the selected category of the cables, and voltage drop per unit length, you can determine the cable size


What cable wire size for 1000 watts aircondition?

The only way to determine the cable wire size needed for a 1000 watt air conditioner is to find the load size. To get the load size you will need to use the formula Amps = Watts or Volts. With that being said, you will need a number 14 copper wire.