To calculate the cable size for a 100 kW load, you would need to consider factors such as the voltage of the system, the type of cable insulation, the ambient temperature, and the installation method. The cable size is typically determined by the maximum current the cable will carry without overheating. Using the formula: Cable size (mm²) = (2 x L x I x R) / (√3 x V x cosΦ), where L is the cable length, I is the load current, R is the resistance of the cable, V is the voltage, and cosΦ is the power factor, you can calculate the appropriate cable size for the 100 kW load.
4cx95mm aws which size of cable gland
To calculate the cable size for a 1500 mm length, you need to consider factors such as the load current, voltage drop, and the type of insulation material. First, determine the current carrying capacity required based on the load. Then, use a voltage drop formula to ensure the drop is within acceptable limits, typically around 3-5% of the supply voltage. Consult cable sizing charts or standards that provide guidance based on these parameters to select the appropriate cable size.
Cable size is determined by current. You did not provide the current, nor did you include the voltage so that we could calculate the current. Please restate the question, and include either the current or the voltage.
35 KVA generator using for load 100 meter length which cable need to used
To calculate voltage drop to size the wire, a voltage must be stated.
To answer this question the size of the cable or the amperage of the load is needed to calculate the correct wire size and connectors to fit the cable.
If you know the size of the load to be served, multiply it by 125% ( times 1.25) and choose a conductor that is rated for that ampacity or higher.
100 kw is the power drawn by the load. to calculate the cable size you need to know the voltage. From that you can calculate the current. this decides the cable size. for example if the voltage is 400Volts then the current flowing in the circuit when the load is 100 KW will be 250 amps. (100,000/400). for 250 amps to flow with out causing excessive heating of the cable the cross sectional area of the copper cable should be 150 sq mm.for a round cross section the diameter will be roughly 15mm.
4cx95mm aws which size of cable gland
To calculate the cable size for a 1500 mm length, you need to consider factors such as the load current, voltage drop, and the type of insulation material. First, determine the current carrying capacity required based on the load. Then, use a voltage drop formula to ensure the drop is within acceptable limits, typically around 3-5% of the supply voltage. Consult cable sizing charts or standards that provide guidance based on these parameters to select the appropriate cable size.
take the full load current 1.732*415*I*0.85*efficiency=115*1000 => I? Depending on the value of the full load current and designed and ambient temperatures of the selected category of the cables, and voltage drop per unit length, you can determine the cable size
refer to ANSI lor..
Cable size is determined by current. You did not provide the current, nor did you include the voltage so that we could calculate the current. Please restate the question, and include either the current or the voltage.
The calculations are worked backwards from the amps used by the load of the circuit. This will be used to select the correct size of the wire. Some stipulations are added depending of the ambient temperature, length from the supply or if the load is a motor. Fusing is then dependant on the wire size that is used.
The NEC has a table that shows what size cable to use with each amperage and where it can be used.
for DC load and if its copper wire the cross section of the conductor wire is generally calculated as 1/4 th of the current rating . Eg for a DC load of 16 amp the copper conductor with 4 mm square is selected.
350mcm