the lowest level of outgoing orifice where there are numerous inlet & out pipes connecting a manhole.
invert level =high level - the reading - the diameter of pipe
The invert level is the base interior level of a pipe, trench or tunnel; it can be considered the "floor" level. Conversely, the crown level is the highest interior level, and can be considered the "roof" level
The Invert Level of a pipe is the level taken from the bottom of the inside of the pipe as shown below.INVERT LEVEL OF PIPESection through pipeWater levelInvert levelCrown of pipe
Get a crow bar and you can easily lift it out. Then you can do whatever you want in the manhole. Also manhole covers scrap at a junk yard for about 10 bucks.
Yes it will give
A manhole invert is the pipeline running across the bottom of the manhole, from the point where the incoming pipe enters until the outgoing pipe discharges the outflow. It is frequently expressed as an elevation level where this pipeline sits.
US = Up Stream invert level DS= Down Stream invert level If detailed on a manhole, the difference being the gradient of pipe in chamber from one end to the other.
the lowest level of outgoing orifice where there are numerous inlet & out pipes connecting a manhole.
A manhole invert is the pipeline running across the bottom of the manhole, from the point where the incoming pipe enters until the outgoing pipe discharges the outflow. It is frequently expressed as an elevation level where this pipeline sits.
Invert elevations can usually be found directly on as-built drawings of the sewer facility. The simplest way to calculate an invert elevation of a manhole is to measure the depth of the manhole from the surface to the pipe invert. The invert elevation equals the ground or rim elevation minus this depth. If you do not know the rim elevation or invert elevation, a surveyor must measure the invert and/or rim elevation with reference to a nearby elevation benchmark (see: http://commons.wikimedia.org/wiki/Image:Elevation_Benchmark.jpg). Also, upstream and downstream invert elevations in a manhole typically differ by about 0.1 feet.
The obvert elevation of a pipe is the elevation of the inner top surface of the pipe (as opposed to "invert" which is the inner bottom surface of the pipe). Invert (and obvert) is usually used in reference to pipe and not manholes, since the invert elevation is where the water flow calculations begin. Based on this interpretation, the obvert (at a manhole) can be measured as the distance from the manhole rim to the inside top of the pipe(s).
Invert Level and Invert Elevation are one in the same. Invert Level = Invert Elevation (IE).
Given one invert, and the length of the pipe and the slope of the pipe, you multiply the the length of the pipe by it's slope (expressed as a decimal ratio) and add the result to the known invert.
invert level =high level - the reading - the diameter of pipe
Invert Level is the bottom of the pipe, reduced level is the middle of the pipe.
The invert level is the base interior level of a pipe, trench or tunnel; it can be considered the "floor" level. Conversely, the crown level is the highest interior level, and can be considered the "roof" level