Depending on the brand of air conditioner, it is either the removal of the signal voltage to the valve, or the constant application of signal voltage to the valve. Most brands on the market are powering the reversing valve in the cooling mode. This would be easiest as you would have to make no changes if you wish, and only switch your thermostat to Emergency heat instead of heat, effectively not using the heat pump. On Rheems and Ruuds for example, the unit is in cooling mode unless the reversing valve has voltage applied to it. If you have a Rheem or Ruud, no change would be necessary except to change your thermostat to a correctly wired standard version rather than a heat pump specific version. Many electronic thermostats have this built in. Like above, you could also simply use Emergency heat instead of normal Heat switch at the thermostat. Either way, heatpump wiring can be tricky for even a good service tech if they aren't accustomed to working with heat pumps. So its best to have this done by a service company that works with heat pumps a bit.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you disable the reversing valve on a heat pump so you can run with a straight cool air handler?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What component allows heat pump to switch between heating and cooling modes of operation?

the reversing valve is what actually changes the refrigeration cycle from heat to cool. the reversing valve receives its signal from the thermostat.


How repair a stuck reversing valve?

first you have to turn the valve and see if it was just in a wrong position


Central unit blowing cool air instead of hot when heat is on?

sounds like t stat is programmed wrong, reversing valve coil is bad or reversing valve is stuck.


How do i disable the ERG valve?

If your EGR valve is vacuum operated, simply remove the vacuum hose from the valve.


Where is the reversing lights switch on a 1998 Plymouth breeze?

Inside the transmission, on the valve body.Inside the transmission, on the valve body.


Where must a suction line be placed in a heat after a motor burnout?

between the comp and the reversing valve


Where must a suction line be placed in a heat pump after a motor burnout?

between the comp and the reversing valve


Central air conditioner a heat pump wheezes when turns off?

Heat pumps have a reversing valve in the outside unit. You are hearing a balance of refrigerant pressures when the reversing is energized or de-energized.


Can you replace your straight cool AC condensing unit to a same size unit with heat pump?

Hi, Good question and the answer is ( YES! ) as long <<<< as you are not taking up any fancy ideas of using it as a heat pump. Wire it in and set the reversing valve to stay on cool cycle and never reverse to heat and viola. Some units use energized reversing valve during cool and some de-energized. Its easy to find out. Just try it. Hope this helps: Jimiwane


Where must a suction-line drier be placed in a heat pump after a motor burnout?

between the comp and the reversing valve


How do you wire a heat pump to straight cool unit?

Hook up common and yellow from inside unit to condenser