Go to www.sloanvalve.com On the left side you'll find a box titled quick select.
Select your flushometer model and the repair guide will come up in a pdf. Troubleshooting on page 6.
Basicly you remove the top retaining ring with a strap wrench to access flush module.
Linky:http://www.sloanvalve.com/maintenancedocs/0816193.pdf
EZ ...Good Luck, Bob
Sloan's website no longer offers decent support. It really depends on the model and type used, but if your referring to a top mount unit you:
A) Remove retaining ring with (ideally) a strap wrench. More frequently a large pair of channel locks will be necessary. It will turn lefty loosey.
B) Remove cap and access flush module.
Depending on how the toilet or urinal is malfunctioning you should try replacing parts in the order of cheapest fix.
.........................................................................................................
1) Replace batteries (if not hard wired)
2) Adjust range of infra-red eye
3) Replace flush diaphragm
4) Replace operating solenoid
5) Replace flush module
.........................................................................................................
C) Remove flush module from seat (depending on cap type may still be attached)
D) Disconnect module to solenoid wire harness.
E) Unscrew and remove both solenoid and cap end with o-rings (new solenoid will come with new cap, but sometimes they stick inside the housing.
F) Separate diaphragm from housing.
G) Re-assemble in reverse.
A defective flush valve causes the leak in toilets. A flush valve is a flap or ball plunger device that is supposed to act as a stopper in the bottom of the toilet tank. So to fix your toilet and save water, get any professional plumber to repair the valve or complete replacement kit . alliedallcityinc.com
If it smokes only on start up, and then quits smoking in a few minutes then the valve seals are bad, and they fit over the valve stem and down onto the top of the valve guide. They stop oil from running down the valve stem and burned in the cylinder. They do not sell anything in a can that will fix that problem. You need to buy valve seals and have them installed by a trained mechanic. And they come in a plastic bag not a can. SORRY NO quick fix.
Nothing is worst than a leaking toilet flush, as it can give a homeowner torrid time to solve the issue. To overcome the problem find the root cause first, in this context a plumbing leak or tension on the flush chain. Most of the times low quality flush valve are also the reason your toilet flush might be leaking. If the DIY thing doesn't help call a plumbing company near you and repair or replace the leaking toilet flush ASAP.
Flush it : that will fix it!
Replace the fill valve (ballcock). The type that uses a diaphragm, like fluidmaster, will shut it off quicker. Reason that occures: vibrations in the pipe from the fill valve when the water flows through the ballcock ( like a whistle does with air), but water makes a deeper sound and sometimes vibrates quite loudly once that starts. If that doesn't fix it, try replacing the supply water valve.
With a new valve gasket
Flush it : that will fix it!
how to fix auto transmission on eunos 30x . no reverse or neutral..
Remove the head and have the valve reseated or replaced.
The car code p0446 is a faulty vent valve. To fix this problem, the vent valve will need to be replaced.
TRY HODESCO FOR THE PARTS YOU ARE LOOKING FOR. THE FLUSH VALVE SHOULD BE THEIR PART 60-126. CONTACT THEM AT 1-800-777-6500 OR WEBSITE WWW.HODESCO.COM
A lady list moderator told me not to go into to much details on fixing things on here as she feels people are not able to comprehend advice (mentally to understand) Without going into technical detail in order to give any advice one has to know if the flushometer is a piston or diaphragm type and and knowing if it is a Coyne Delany Rex, Sloan royal, Sloan Gem , Turn to silence flush boy would sure help a lot