Want this question answered?
the delay line is used to delay the incoming signal vertical information and synchorized it with the horizontal
When a signal of 10 mV at 75 MHz is to be measured then which of the following instrument can be used -
CRO is an analog instrument.
There are 2 types of CRO probes a. Active Probes (9 Megaohms) b. Passive Probes - hig voltage probe (10 to 1000 Megaohms)
The cathode ray oscilloscope is basically a measuring instrument. Time period of any sinusoidal signal can be measured along X-axis.Other applications of CRO is the calculation of peak to peak voltage,current of any signal and the phase difference between the two signals can also me determined.The uses of the oscilloscope are as follows:To display the wave forms of ac and dc signals.It helps to specify the amplitude of the signal on the y-axis and the period on the x-axis.
An attenuator is an electronic device that reduces the amplitude or power of a signal without appreciably distorting its waveform. attenuator just decrease its amplitude and the attenuator you can take it as a opposite of amplifier. Amplifier just modifies the input signal gives amplified output signal
DSO (Digital Storage Oscilloscope) and CRO (Cathode Ray Oscilloscope) are both test instruments used for viewing and analyzing electronic signals. The main difference lies in their display technology, where a DSO uses a digital display while a CRO uses a cathode ray tube for visualization. DSOs offer more advanced features like storage capabilities, data processing, and connectivity options compared to CROs.
using CRO we can measure the rise time and fall time of the capacitor for further studies
Type your answer here... 450000 hz
function generator generates different types of functions to cro. And it can send analog signals to cro to create their graphical representation, and by it we can vary frequency and amplitude of the given wave function
function generator generates different types of functions to cro. And it can send analog signals to cro to create their graphical representation, and by it we can vary frequency and amplitude of the given wave function
function generator generates different types of functions to cro. And it can send analog signals to cro to create their graphical representation, and by it we can vary frequency and amplitude of the given wave function
Cro-Magnons made tents using mammoth bones as supports
Cathode ray oscilloscope(CRO) is a device used to see the voltage across a particular element of your circuit and the wave form can also be seen on CRO. But you actually cannot measure the current using CRO as it is meant to give the voltage levels across any element in eletrically enegized circuit. however Digital Multimeter can do this job. But while using DMM to measure current one thing should be kept in mind that your circuit should be linear so that if you break the circuit to find current in series the current could not change in circuit.
The Cro-Magnon, classified as early modern humans, did not die out as a distinct group; they are considered the same species as modern humans. Their lineage evolved over time into what we are today.
The oldest known cave paintings by the Cro-Magnon are 32,000 years old.
The Amplitude of a sound is it's loudness. It is possible to convert a sound wave into a transverse wave and see it on a CRO. (Cathode Ray Oscilloscope) A quiet sound has a low aplitude and a loud sound therefore has a high amplitude.