The relief valve should be at least as large (in BTU/hr capacity) as the input of the boiler. A 3.5 million input boiler would need then a relief valve to handle at a minimum 3.5 million BTU/hr.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you size a boiler relief valve?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What to do if your furnace keeps blowing water out of the relief valve?

Nothing as a furnace is scorhed air a BOILER is either water or steam and "Relief Valves" are for liquid thus either you have a boiler or your furnace is being flooded from an outside source


What is the difference between an air bleed valve and a pressure relief valve on a boiler?

They serve two different purposes. An air bleed valve is used to remove air from the circulation system. A pressure relief valve is designed to automatically open when certain pressure levels are reached.


Why does a boiler explode?

Low water level along with both a defective high limit safety and pressure relief valve.


Why two safety valve provide to boiler?

standby valve,


Can a broken thermostat on an oil boiler cause hot water to flow out through the expansion pipe?

Yes, the water is getting too hot and is blowing out the pressure relief valve through the expansion tank. You should change this immediately.I don't agree:I am assuming that by expansion pipe, you are referring to the pipe connected to the pressure relief valve - A broken Thermostat won't cause the relief valve to activate. A broken thermostat will cause the boiler to either run or not run as desired. However, a broken (or incorrectly set) aquastat can cause the boiler to run too hot and cause the valve to activate, but if it is chronic, it could be a defective or dirty relief valve, defective expansion tank, a problem with the pressure reducing valve on the domestic feed or (as was my problem) an internal leak in my tankless coil.What is your boiler's pressure gauge reading and what does the Temp Gauge read on a call for heat (High Limit on and off)? Also, put a bucket under the pipe and carefully burp the relief valve to clear out any debris that might be causing the leak.


Should a Pressure Relief Valve be installed on a boiler hot water system?

Yes ( always ) and make sure it is rated for the B.T.U.


Why does a house boiler pressure relief valve drip water constantly?

if it's dripping water constantly even when cold most likely your pressure reducing valve on the in coming water is letting in more water than it should causing the pressure to rise, if it just happens when the boiler is calling for heat it's probably your expansion tank, it could be water lodged and needs to be drained and re pressurized or replaced. make sure the pressurizer relief valve is not dripping before your boiler reaches 30 psi, that's what they are usually set for on house boilers, if it is dripping before reaching 30psi it's a faulty pressure relief valve that needs to be replaced


Can you use a bladder pressure tank even though the bladder is leaking?

If your bladder is damage in any way, your boiler will run but you will have other problems.If your expansion tank is not working, you will be seeing water leaking out of the Pressure Relief Valve when pressure gets around 30psi (most residential boilers). The water may stop dripping when the boiler reaches its highest temperature, but once the boiler starts cooling down, water will start contracting causing low pressure. This will cause the automatic fill valve to let water back into the boiler thus making the water drip out the relief valve again when it heats up.DO NOT shut off the water inlet valve. This could cause high damage or seriously injury if you run out of water.You should replace the tank and also the relief valve to be safe. Call a licenced plumber.


How do you test a safety valve of a Boiler?

Raise the pressure in the boiler until the valve relieves and note the pressure at which it does so.


What is the application of boiler stop valve?

Stop Boiler Valve (or Crown Valve) is installed on an outlet line of a boiler. It's purpose is isolation of a boiler from a downstream steam line. Its position may be either open or close, it cannot be used for throttling of steam.


Where does the pressure relief valve goes on a coil for domestic hot water coming out of boiler?

The hot water usually goes to a storage tank. The PRV goes there, near or at the top.


What is the feed check valve of boiler?

The feed check valve of a boiler is on the line coming out of the boiler it is usually to prevent the water from going back in to the boiler its coming out of so it would build up excessive amounts of pressure which will cause the t&p valve to blow temperature and pressure