with an meg ohm meter

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

Procedure for sumpners test?

Procedure for sumpners test is the single phase transformer. This is a back to back test.


What is load test on single phase transformer?

A load test on a transformer is done to make sure it stays within its designed temperature range while on full load.


What is the current of 1MVA transformer?

This depends on the voltage, and whether it is a three phase or single phase transformer.


How do you zero phase current tranformer test?

How do you zero phase current transformer test


Load test on single phase transformer?

The dc tests that can be done on a transformer are to measure the resistance of each windings and to measure the insulation resistance between the windings and between each winding and the transformer case.


How do you convert a 3-phase system to a single phase?

By having a transformer with 3 phase input and single phase out put


Why the need of harmonics in single phase transformer?

Harmonics are really not needed in single phase transformers.


What is this system called with three single phase transformer?

Your question is rather vague. If you are asking what do you call a group of single-phase transformers, connected to supply three phase, then the answer is a 'three-phase transformer bank'.


How you differentiate between single phase and three phase transformer?

A single-phase transformer works with a single-phase supply, while a 3-phase transformer is used with a 3-phase supply. A single-phase transformer has 2 wires on the primary and secondary (ignoring taps) while a 3-phase tansformer has 3 or 4 wires on the primary and secondary.


What is the procedure to polarity test a 3 phase transformer?

A 'polarity test' is conducted on a single-phase transformer, not a three-phase transformer (or transformer bank). The polarity of a single-phase transformer being important if two transformers are to be connected in parallel, or three transformers are going to be connected to form a three-phase transformer bank.'Angular displacement' is, to a three-phase transformer, what 'polarity' is to a single-phase transformer. So you really should be asking about angular displacement, rather than polarity. Angular displacement, or 'phase displacement', is the angle by which the secondary line voltage lags the primary line voltage.Angular displacement can be determined either by drawing a phasor diagram of the three-phase connection and measuring it, or by looking up the connection in a vector-group chart/table -you would nor normally 'calculate' angular displacement.


How do you design a transformer with three phase 400v input and single phase 2000v output?

By design are you going to wind the transformer yourself? In your design you need a 5:1 ratio. On the output side of the transformer any two legs of a three phase transformer is considered single phase voltage. Good luck on your project.


What is the purpose of conducting sc and oc test of single phase transformer?

The purpose of conducting sc (short circuit) and oc (open circuit) tests on a single-phase transformer is to determine its equivalent circuit parameters, such as the winding resistance, leakage reactance, and magnetizing reactance. These tests help to evaluate the transformer's performance and efficiency under various operating conditions.