Procedure for sumpners test is the single phase transformer. This is a back to back test.
The temperature rise is not considered in OC & SC tests of transformers.. But in Sumpner's test, temp. rise is considered.. Hence is called "Heat-run test".. Also, the transformers draw only the power req. to supply core & Cu. losses of transformer..
The 'Safe Isolation Procedure' is a procedure carried out to ensure that you are working safely on electrical equipment. Firstly, you isolate the power at the fuse board. It's best to switch each circuit off one by one starting furthest away from the main red switch (I'm not 100% sure why but its something to do with voltages). You then erect barriers and signs. You then lock off at the main switch and remember to keep the key on your person. After this you use a certified voltage tester (preferably a gs38) to check if the board is dead. Give the tester a thorough inspection check leads and probes and then use the proving unit to check it's not faulty. After this you then test at the board main L to main N, then main L to man E, then main N to main E (3 point test). You then test at your proving unit again to check testers not faulty and then commence work.
magnetising current test, magnetising balance test, s.c test, vector group test, winding resistance test, ratio test
On installed transformer a test is performed to check weather it has any oil leakage or not, the test is called pressure test, more precisely pressure leakage test.
Short circuit test and open circuit test are widely used to test the efficiency of the transformer.
sumpners test is performed to find core losses and copper losses.here we can find effieciency and regulation by actually simulating the loading conditions.hence the results obtained by this method are more accurate than oc and sc test where loading conditions are absent.we can perform heat run test which is an advantage of sumpners test as both losses occur simultaneously
Its a test conducted on two identical 1- phase transformers to determine the efficiency at different loads (without actually connecting any load).
The temperature rise is not considered in OC & SC tests of transformers.. But in Sumpner's test, temp. rise is considered.. Hence is called "Heat-run test".. Also, the transformers draw only the power req. to supply core & Cu. losses of transformer..
is test tube baby is procedure is painful?
What is the procedure for hydro-testing?
What is the procedure for hydro-testing?
The name of this procedure is experiment.
The name of this procedure is experiment.
test procudure
step=by-step procedures Unit testing is a procedure
You can get the information about stucco has a pull test procedure and or NOT from architecture.about.com/library/bl-preservationbrief-stucco02.htm
bi