Hook a fuel pressure gauge up to the shrader valve on the fuel rail.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

How do you test the fuel pump for 1993 mercury villiger?

Fuel pump pressure test.


Injection Timing Control Circuit Malfunction on 2001 dodge Cummings?

Failed injection pump, also test fuel flow from lift pump.


How do you test a fuel float sensor 1993 Dodge Dakota?

To test the fuel float sensor on a 1993 Dodge Dakota, first, remove the fuel tank access panel to reach the fuel pump assembly. Disconnect the wiring harness from the fuel level sensor and use a multimeter to measure the resistance across the sensor terminals while moving the float arm up and down. The resistance should change smoothly between approximately 0 to 90 ohms as the float moves. If the readings are inconsistent or outside this range, the sensor may be faulty and should be replaced.


How do you test the fuel pump relay on a 92 dodge shadow?

I believe that you can switch the Horn Relay with the Fuel Pump Relay and if the horn no longer works and the Fuel Pump does then that relay went bad... try that, its a sure fire way to know whats wrong... If it checks out good it might be a Defective Fuel Pump.


How do you test fuel pump on 1993 Suzuki vs 800 intruder?

To test the fuel pump on a 1993 Suzuki VS 800 Intruder, first, ensure the bike is off and safely secured. Disconnect the fuel line from the pump and place it into a container. Then, turn the ignition key to the "ON" position (without starting the engine) and listen for the pump's operation; it should hum for a few seconds. If no sound is heard or fuel does not flow from the line, the pump may be faulty and should be tested further or replaced.


How do you tell if fuel pump or fuel pump relay --1993 Audi 90CS?

To determine if the issue lies with the fuel pump or the fuel pump relay in a 1993 Audi 90CS, start by checking for power at the fuel pump while the ignition is on. If there’s no power, the relay may be faulty; you can test the relay by swapping it with a similar one in the fuse box. If power is present but the pump isn't working, the fuel pump itself might be the problem. Additionally, listen for a humming sound from the fuel pump when the ignition is turned on, indicating it's functioning.


Where is the fuel pump in a 1993 Ford Thunderbird?

The fuel pump is located on the top of the fuel tank. The sending unit and fuel pump are one unit. Test access to wiring can be gained by an access cover under the lower back seat. Pump can only be changed by droping the tank. Hope this helps!


How you check fuel pump in 2006 dodge charge?

To check the fuel pump in a 2006 Dodge Charger, start by listening for the fuel pump's activation sound when you turn the ignition key to the "ON" position without starting the engine. If you don’t hear it, you can check the fuel pump relay and fuse to ensure they are functioning properly. Additionally, you can use a fuel pressure gauge to test the fuel pressure at the Schrader valve on the fuel rail; refer to the specifications for the correct pressure range. If the pump is not working or the pressure is low, it may need to be replaced.


How do you test a fuel pump 96 tracer?

Fuel pressure test at the fuel rail.


How do you run a test on the fuel pump?

Fuel Pump Pressure Test Look at the Related links below for help.


How do I know if my fuel pump is bad?

A fuel pump pressure test could determine the condition of the fuel pump and fuel system.


98 dodge neon won't start turns over fine has spark fuse and relay fine as well as fuel pump no power to fuel pump plug?

Test for a broken wire between the fuel pump and power distribution box. Check for bad connectors also.