If a product like wd40 does not work easily Get a new gas valve, Why risk loosing your house over a 100-200 dollar part. If the gas on your car was stuck well you get it.
Yes, a Laars Lite 2 heater can be used with a saltwater pool, but it's important to ensure that it is compatible with saltwater systems. Saltwater can be more corrosive than traditional chlorine, so you should check for any specific guidelines or recommendations from the manufacturer regarding saltwater use. Regular maintenance and monitoring of the heater's condition are also advisable to prevent potential corrosion issues.
Good chance its your hot surface ignighter that has broken. Check to make sure that there is 120 v or far more common 220v at fenwal Depending if heater is wired for 120v or 240v. If proper voltage is present ignighter is broken. by zoomy
Have the thermocouple checked or spillage from down draft and make sure there is free air for proper combustion
When was the last time the filter was cleaned? Have all the components in the heater system been checked for proper values? Does the heater sound as if it wants to fire up? Does it have a pilot light or electronic ignition? Have the orifices been checked for bugs or spiders? Ken
Yes, a heat exchanger can be replaced on a Laars Lite 2 LD400P. However, it is important to ensure that you obtain the correct replacement part and follow the manufacturer's guidelines for installation. If you're not experienced with boiler maintenance, it’s advisable to hire a qualified technician to perform the replacement to ensure safety and proper functioning.
If the pilot light on your Laars Teledyne Lite 2 model LLG 125 does not stay lit after replacing the gas valve and pilot burner assembly, check for proper gas supply and ensure there are no blockages in the gas line. It's also important to verify that the thermocouple is functioning correctly; it may need replacement if it fails to generate sufficient voltage. Additionally, inspect the venting system for any obstructions that could affect combustion and pilot operation. If the issue persists, consulting a qualified technician may be necessary for further diagnosis.
No.
The thermocouple only keeps the pilot light. Temp sensor,gas valve, high limit switch, safety switch,thermostat, would cause burner not to stay lite. Better to post MFG,model, problem. lenox,model #, ______________________________
Replacing the thermocouple that the pilot flame touches when it is lit will fix the problem 90% of the time. A thermocouple costs about ten dollars and allows the gas to the pilot and main tube to flow by generating millivolts from the heat of the pilot flame. The thermocouple is a copper wire attached by a small nut to the main gas valve near the pilot tube coming out of the gas valve.
High winds, pilot generator. Is the heater located next to a wall? Is the heater door closed? Does the heater have a draft hood or what they call a stackless heater? Ken
my g6 heater and shifter console does not light up
Assuming you are getting that measurement at the valve would indicate a strong pilot generator and if the valve still will not open then I would pronounce the gas valve DOA. To replace the valve cost can vary from $350 to $650 depending on the Contractor due keep in mind that you've replaced the Pilot Generator and now a valve to finsh the job right install a new Pilot Body with the correct orifice and that will round out a reliable system. Good luck! Tim J&K Heating and Cooling Inc.