i think you subtract the evaporator temp from the outside temp?
To determine the superheat for an air conditioner, you need the evaporator's suction line temperature (measured with a thermometer) and the corresponding saturation temperature for the refrigerant being used at the same pressure (obtained from a pressure-temperature chart). The superheat is calculated by subtracting the saturation temperature from the measured suction line temperature. Additionally, knowing the manufacturer's specifications for the appropriate superheat range for the specific system is essential for optimal performance.
Air has a pressure, but not a suction pressure. Air pressure is measured with a barometer, you do not calculate it. Suction pressure is a concept which applies to a pump. Suction pressure = static pressure + surface pressure - vapour pressure - friction pressure.
The proper suction pressure of any air conditioning or refrigeration system is determined by the type of refrigerant used and sometimes the amount of charge. : Suction pressure used is also directly related to the temperature required. : The temperature required in the evaporator relates to the pressure required in the suction line since, the fluid is at saturation in the evaporator. : Knowing the temperature required, use the fluid's saturation tables to find the corresponding pressure required.
-5 something is wrong
An increase in the ambient temperature can cause the suction pressure to rise, as warmer air entering the system raises the pressure. Additionally, any restriction in the refrigerant flow or a dirty filter can also lead to a rise in suction pressure.
The suction line connects the evaporator outlet and the compressor intlet. Low pressure refrigerator vapour is drawn from the evaporator to the compressor through this line.
"What" on the suction line of an air conditioner indicates a problem?
Generally, as fan speed increases, suction pressure tends to decrease. This is because increased fan speed results in greater airflow across the evaporator coil, which enhances heat transfer and cooling efficiency, leading to lower suction pressures. Conversely, decreasing fan speed can lead to higher suction pressures due to reduced airflow and heat transfer capabilities.
non condensebles in system dirty cond coil high ambient poss over charge
when pressure on the suction side of the pump drop below the vapour pressure of the liquid, vapour forms. It's caused because of insufficient suction head, high suction lift, excessive friction head, or high liquid temperature.
A suction line is usually cold to the touch.
The suction pressure of R-407C gas typically ranges from 70 to 110 psi, depending on factors such as ambient temperature, system design, and operating conditions. It is important to consult the manufacturer's guidelines and specifications for the specific equipment or system being used to determine the appropriate suction pressure.