answersLogoWhite

0

The suction pressure of R-407C gas typically ranges from 70 to 110 psi, depending on factors such as ambient temperature, system design, and operating conditions. It is important to consult the manufacturer's guidelines and specifications for the specific equipment or system being used to determine the appropriate suction pressure.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

How do you calculate suction pressure for air theoretically?

Air has a pressure, but not a suction pressure. Air pressure is measured with a barometer, you do not calculate it. Suction pressure is a concept which applies to a pump. Suction pressure = static pressure + surface pressure - vapour pressure - friction pressure.


What is the effect of high gas suction pressure in a gas compressor?

High gas suction pressure in a gas compressor can lead to increased power consumption, reduced compressor efficiency, and potential damage to the compressor components due to excessive load. It can also result in higher discharge temperatures and potential overheating of the compressor.


What the 134a gas normal suction and discharge pressure?

For R-134a gas in a typical air conditioning system, normal suction pressure ranges from 25 to 40 psi, while discharge pressure ranges from 175 to 260 psi. These pressures can vary based on factors such as ambient temperature, equipment efficiency, and system design.


What are the causes of high suction pressure?

Common causes of high suction pressure in a refrigeration system can include a dirty or blocked evaporator coil, low airflow due to a dirty filter or a malfunctioning blower motor, overcharge of refrigerant, or a faulty expansion valve. It could also be due to issues with the compressor such as overheating or mechanical failure.


What is the fan speed relationship to suction pressure?

Generally, as fan speed increases, suction pressure tends to decrease. This is because increased fan speed results in greater airflow across the evaporator coil, which enhances heat transfer and cooling efficiency, leading to lower suction pressures. Conversely, decreasing fan speed can lead to higher suction pressures due to reduced airflow and heat transfer capabilities.

Related Questions

How do you calculate suction pressure for air theoretically?

Air has a pressure, but not a suction pressure. Air pressure is measured with a barometer, you do not calculate it. Suction pressure is a concept which applies to a pump. Suction pressure = static pressure + surface pressure - vapour pressure - friction pressure.


Does low suction pressure have an effect on reciprocating compressors?

At very low suction pressure, the suction valves of reciprocating compressor will not work and there will be no gas in the cylinder during compression stroke, resulting some damage to the suction valves. If low suction pressure trip protection is not provided there can be some abnormal damage.


What is the effect of high gas suction pressure in a gas compressor?

High gas suction pressure in a gas compressor can lead to increased power consumption, reduced compressor efficiency, and potential damage to the compressor components due to excessive load. It can also result in higher discharge temperatures and potential overheating of the compressor.


Is suction pressure another word for evaporator saturation pressure?

No, suction pressure refers to the pressure of refrigerant gas leaving the evaporator and entering the compressor, while evaporator saturation pressure refers to the pressure at which a refrigerant changes from a liquid to a vapor in the evaporator coil. They are related but not the same.


What the 134a gas normal suction and discharge pressure?

For R-134a gas in a typical air conditioning system, normal suction pressure ranges from 25 to 40 psi, while discharge pressure ranges from 175 to 260 psi. These pressures can vary based on factors such as ambient temperature, equipment efficiency, and system design.


Where is suction and discharge s?

Answer: The terms suction and discharge are the terms refer to hydraulics. In hydraulics if the the liquid has to be lifted or pumped to the usage area the hydraulic pump will be used . This pump will have to functions that is first suction to lift the fluid and the discharge or delivery . The familiar words in pair are lift and discharge; suction and discharge. The specification of pump for these terms are suction head and discharge head.AnswerThe suction pressure refers to the pressure of the referigerant being "sucked" back into the compressor. The suction pressure is a critical variable in ensuring the accuracy of the refrigerant charge, along with the tepmerature of that line as well. The "superheat", or heat added to the vapor in that line can be monitored in this manner.You have not mention which suction pressure... Actually Where ever the suction is presented that pressure is called suction pressure.... and suction pressure in practical cases normally always less that atmospheric pressure and in case of delivery pressure it is oppositeSaying that suction pressure is " the pressure of the referigerant being "sucked" back into the compressor " is not accurate.Simply , the suction pressure of a pump is the absolute pressure of a fluid , measured at the inlet of the pump ( in your answer , the pump is the compressor , and the fluid is whatever refrigerant. )The discharge pressure , is the absolute pressure of the liquid measured at the outlet of the pump.Obviously, the discharge pressure is usually bigger than suction pressure.


What is suction?

An A/C compressor sucks refrigerant gas from the evaporator inside the car and compresses it into high pressure liquid. So the tubing that goes from the evaporator inside the car to the compressor is called the suction line.


What is the suction pressure of condensate extraction pump?

Condensate pump suction pressure below 4 feet of the condenser is almost equal to condenser pressure (760mm of Hg). If the pump equiped under the deep pit , suction pressure is vary.


What is an ac discharge and suction lines?

AC discharge and suction lines are components of an air conditioning system. The discharge line carries high-pressure refrigerant gas from the compressor to the condenser, where it releases heat and condenses into a liquid. In contrast, the suction line transports low-pressure refrigerant gas from the evaporator back to the compressor, where it is compressed and cycled again. Proper insulation and maintenance of these lines are crucial for efficient system performance.


What will cause the suction pressure to rise?

An increase in the ambient temperature can cause the suction pressure to rise, as warmer air entering the system raises the pressure. Additionally, any restriction in the refrigerant flow or a dirty filter can also lead to a rise in suction pressure.


How does suction get measured?

Suction is typically measured using a device called a manometer, which compares the pressure of the suction with atmospheric pressure. The difference in pressure is then quantified in units such as inches of mercury (inHg) or millimeters of mercury (mmHg). Alternatively, vacuum gauges can also be used to measure suction.


What is back pressure in a home ac unit?

Suction pressure