1) If current, at 'on load' condition, reach or cross its rated value, then the speed of the motor will be decreased. 2) If there is any voltage droop occurs in the incoming supply then the speed of the motor will be decreased.
A 2-pole motor has about 1.5 ft-lbs of torque per horsepower where a 4-pole motor has 3 ft-lbs of torque. also the speed of a 2-pole motor is twice that of a 4-pole motor. The speed of a motor is determined by: speed=(120 x freq)/no. of poles At 60 Hz, a 4-pole motor is about 1800 rpm where a 2-pole motor is 3600
It depends on the motor. They can be purchased with different numbers of poles. The number of poles mainly changes the speed of the motor.
Yes,provided that the power output of the investor is higher than the motor's rated power.
An induction motor rotating at higher than synchronous speed would be generating power, thus would be a generator. No motor operating as a motor runs above synchronous speed.
Mutli speed furnace motors work on a basis of horse power verses work load. The motor actually contains multiple windings or you could say multiple motors. Each of the windings has a specific horse power rating at a given work load. For example, a 3 speed 1/2 horse power motor is actually 3 different horse powers. High is 1/2 hp - medium is 1/3 hp - low is 1/4 hp. As the motor horse power is decreased the motor will slow down under a given or constant work load. Technically there is no such thing as a multi speed motor but in actuality a multi horse power motor.
Several possibilities are that: 1 the switch is bad on the high position. 2. There is a problem with the high speed wire from the switch to the motor. 3. The wiring inside of the wiper motor for the high speed is bad. The way 2 speed wiper motors work is there are separate windings inside the motor for low and high speeds. Usually 2 wires come out of the motor for low and high and the common ground through the wiper motor body to the chassis of the vehicle. You apply 12v to one wire and get low and 12v to the other one for high speed.
If the one speed it works on is high speed, it is the blower motor speed resisitor that is bad.
I would suspect the blower motor speed resister is shot.
The blower motor speed resistor is burned out. The high speed function bypasses the resistor. The speed resistor is generally located near to the blower motor.
change the blower motor resistor . this controls the speeds . thanks paul
the blower motor resistor is broken, get a replacement.
If you are saying the blower motor will not work, then check the fuse. If the fuse is not blown, then it is possibly a defective Blower Motor Resistor Pack, blower motor, or blower motor speed control switch, in that order.If you are saying the blower motor will not work, then check the fuse. If the fuse is not blown, then it is possibly a defective Blower Motor Resistor Pack, blower motor, or blower motor speed control switch, in that order.
1) If current, at 'on load' condition, reach or cross its rated value, then the speed of the motor will be decreased. 2) If there is any voltage droop occurs in the incoming supply then the speed of the motor will be decreased.
Honda Manual Transmission Fluid is recommended for a 5-speed manual B16A motor. Amsoil Manual Transmission Fluid will also work in a 5-speed manual B16A motor.
replace blower resistor
This motor is able to work from the battery. The speed is less complicated to use and you do not need much voltage.