Three: Live, Neutral and Earth
A single-phase cable will have a line and a neutral conductor and, possibly, but not necessarily, an earth (ground) conductor. A high-voltage three-phase cable will have three line conductors. A low-voltage three-phase cable is likely to have three line conductors and a neutral conductor.
100 amps to a 3 phase load. Power = 100A x Voltage x 1.73 ((line to line voltage)(1.73=SQRT(3)). 173 amps to each of 3 single phase (line to line) loads. Power = 173A x Voltage (line to line voltage). or... 100 amps to each of 3 single phase (line to neutral) load. Power = 300A x Voltage (line to neutral voltage). Example: - 3 phase, 480v, 100amp to a 3 phase heater. 100A x 480V x 1.73 = 83040 watts. - 3 single phase 480v (L-L voltage) heaters, 100amp. 173A x 480V = 83040 watts. - 3 single phase 277v (L-N voltage) heaters, 100amp. 300A x 277V = 83100 watts.
1TR = 3.5KW in Single phase and 1.2KW in 3-phase
For a single phase circuit, the equation you are looking for is I = W/E. Amps = Watts/Volts.
You can divide a three phase service into (3) single phase circuits providing you have a 4th neutral wire.
A single substance has one phase.
The conductors between a three-phase supply and a three-phase load are called line conductors not phase conductors, and the voltage measured between them are line voltages, not phase voltages. In the case of a delta supply, the line voltages are numerically equal to phase voltages, but the name remains the same!I have to admit that many people call line conductors 'phase conductors', but many people also say 'irregardless' -that doesn't make it a real word!!
If the transformer is three phase the calculation is I = 30,000 / 1.73 E. If the transformer is single phase the calculation is I = 30,000 / E. (Where I = current and E = secondary voltage) It is important to note the voltage in the first formula is line to line (typically how it is specified in three phase power systems), and the second formula it is line to neutral.
the term ''homo" and "geneous" mean ''single" and "phase" respectively, hence,the name homogeneous indicates the single phase so,there are just one phase in homogeneous.
There is only one ground wire needed on any motor, single or three phase.
50 Amps Single Phase 20 Amps Three Phase
Verify wiring layouts by making measurements, before connecting and/or energizing equipment. A 120V single phase 2 wire should have one hot wire, a 230V single phase 2 wire should be assumed to have two hot wires, and a 230V single phase 3 wire also should have two hot wires.