answersLogoWhite

0

How many mega ohms to trip rcd?

Updated: 12/4/2022
User Avatar

Wiki User

13y ago

Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: How many mega ohms to trip rcd?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is an RCD cut the current to a circuit?

RCD cut the current to the circuit while preventing the electric shock


Can you megger or test an rcd?

yes


What is residual curent?

Residual current as in a residual current device or RCD (sometimes known as a earth leakage detector), refers to the current both entering and leaving a circuit. If more current flows into a circuit then comes out (if there is a ground fault or if someone gets a shock) the RCD will switch off the circuit. Typically the current required to trip a RCD is around 5-20mA, however even 5 mA can be enough to stop your heart, so RCDs are a good safety device but should not be relied on.


What is the full form of MCB?

The definition of MCB is a miniature circuit breaker, it trips if there is a line to natural fault. Ill add some extra information about the different types. RCD - residual current device = This is what you could separate you're circuits up with by inserting 1 of these in you're consumer unit (if you have lets say 10 circuits it goes like this... rcd-mcb-mcb-mcb-mcb-mcb-rcd-mcb-mcb-mcb-mcb-mcb-main switch. you see the rcd's control 5 circuits each, if 1 of these circuits had an earth fault on it, the rcd will trip and 5 of them circuits will go off, which means you have to keep tripping in you're rcd with an mcb 1 at a time to see which circuit the fault is on. RCBO - residual current breaker with overload protection- These can be installed in place of mcb's and rcd's, the rcbo is an mcb and rcd in 1 breaker. For example, i have installed a consumer unit full of these, in this case if a circuit forms a fault then its only that circuit that goes off. I hope this extra piece of information helps you along and best of luck. <<>> In electrical terminology MCB stands for Miniature Circuit Breaker.


Why do we use additional rcd for earth fault protection?

A 'standard' fuse requires the current to reach a certain level before it blows. This could theoretically cause a user to suffer an electric shock before the fuse 'blows'. An RCD device monitors the current in the circuit and trips a re-settable switch when the current exceeds a safe level. RCD devices react much quicker than the old-fashioned fuses.