answersLogoWhite

0

How many voltage applied in field winding of dc motor?

Updated: 8/17/2019
User Avatar

Wiki User

11y ago

Best Answer

110

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How many voltage applied in field winding of dc motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What field setting for a dc shunt motor wired in series on high voltage?

A shunt dc motor has quite different characteristics from a series motor. Wired in series, the same current passes through the armature and the field winding and it is most unlikely that a shunt motor would have a field winding that is suitable for this. Therefore a shunt motor cannot be wired as a series motor in general because its field winding is designed for only a small current.


Why would a dc motor show high amps no voltage and struggle to turn?

The current flowing in a dc motor is determined by (Applied voltage-Motor EMF) divided by armature resistance. The motor emf is a function of the field excitation of the motor and the speed at which the motor turns. When the motor starts, there can be no EMF because motor speed is 0 rpm. Therefore the motor will draw more current. But as the motor begins to speed up, if it has field excitation, it has to build up EMF and the current will drop. So : If the motor shows high amps and no voltage and struggles to turn the possible reasons are: 1. The motor has no excitation - The permanent magnets are weak or the field winding is faulty or the field is not being supplied. 2. The armature winding is faulty - it has shorted windings. This assumes your supply is healthy of course.


What will happen to the transformer if double the rated voltage is applied to the winding during the open circuit test?

no voltage will be induced on the secondary side of the motor as the windings will become saturated.


How is the synchronous motor made self starting?

The synchronous motor is made self starting by providing a special winding on the rotor poles, known as damper winding or squirrel cage winding. AC supply given to the stator produces a rotating magnetic field which causes the rotor to rotate, therefore, in the beginning synchronous motor provided with damper winding starts as a squirrel cage induction motor. The exciter moves along the rotor. When the motor attains about 95%of synchronous speed, the rotor winding is connected to exciter terminals and the rotor is magnetically locked by the rotating field of the stator and the motor runs as a synchronous motor. While starting a synchronous motor, the field winding must be shorted through a suitable resistance so that the induced voltage is distributed throughout the whole winding and no part is subjected to the high voltage induced in the entire winding.


What happens if field winding of a running dc shunt motor suddenly breaks open?

when the field winding of a running dc shunt motor suddenly breaks open the motor fails to run because in the motor the stationary winding is armature and rotatory is field winding


Can a shunt field winding be used as a series field winding in dc series motor?

aster


How potential relay works in refrigeration?

A potential relay operates on the voltage potential created by the induced voltage in the starting winding of the motor. It is an electromagnetic switch whose coil is wired directly in to the motor circuit. When power is applied to the circuit, the motor starts . As the motor attains its running speed the start winding acts as an auto generator and the voltage potential produced energizes the relay coil which cuts out the start capacitor and the start winding . The start winding still acts as an auto generator , however , and continues to produce enough power to keep the relay energized.


What happens when a high AC voltage is used on a low DC voltage motor?

Depending on the type of DC motor, it will either run normally or just heat up and make noise.i think the motor will rotate to and frow.means it will rotate in clycle.it will complete half cycle.and after it will complete its other half cycle in anticlockwise direction.


What is the function of field winding in DC generator?

The motor needs the current and magnetic flux to create motion The magnetic field is created by field winding where as armature carries the current resulting into the rotation of armature


How schrage motor works?

The Schrage Motor, Model 8234, is a variable-speed polyphase AC motor with both high torque and efficiency. It requires standard three-phase power. The Schrage Motor is used in a variety of industrial applications, such as packaging machinery, conveyors, pumps, and knitting machines, where full torque is needed over a variable speed range. The motor is basically a special wound-rotor motor in which a built-in variablefrequency source is connected to one winding, while the network frequency is applied to the other winding. The voltage of the variable frequency source can be set over a certain range and the resulting speed of the motor depends upon this setting. The Schrage Motor circuit diagram pictured in Figure 1 shows that the primary winding is on the rotor and the insulated secondary winding is on the stator. On the rotor, there is a tertiary, or control, winding, which is connected to the secondary windings on the stator via a commutator and three pairs of adjustable brushes lying on the commutator. When the brushes in each pair move apart or closer together, a variable voltage is applied to the secondary winding by the tertiary winding. The change in voltage varies the speed of the motor below and above synchronous speed.


What happens if load of DC series motor is disconnected?

In D.C Shunt motor, the field winding is connected parallel with the armature winding.. If you remove the supply to armature winding, the motor will stop after some time.


What would the power loss be if the series field winding of dc motor connected directly across the 240 V dc supply?

Detailed Solution. For a constant back emf, flux is inversely proportional to the speed of the motor. If field winding is disconnected accidentally, the speed would dangerously increase in order to maintain the back emf of the motor