40 times more expensive then copper tubing
In general you would only do this if you need to connect a section of brass piping to a pvc section.
Brass and steel are compatible, Otherwise we could NOT use brass valves with steel piping.
In a decent plumbing supply store.. I had one brass wrench I used exclusively on gas piping to prevent sparks
It is NOT Better as RED Brass is 85% copper 15% Zinc and Yellow brass is 60% copper and 40% Zinc and over time the yellow brass becomes brittle because of dezincification. A piping system is only as strong as its weakest joint and BRASS is normally threaded thus the wall thickness is severly reduced, copper tubing Type K, L soldered or brazed are much stronger then threaded brass and Brazed brass piping is stronger but normally cost prohibitive to the average building owner. For more information type Tieger plumbing on any search engine
Of course NOT A Problem as electrolytic action most of the times happen between piping that contains galvanized coating (Zinc) Cast Iron radiators for example have BRASS valves which can contain as much as 85% copper If one looked at the clean outs of cast iron piping the CO's are brass with never any adverse actions
-It's the only brass instrument played with only the left hand -It can play in a brass or woodwind ensemble -It consists of 12 to 13 feet of metal piping
-It's the only brass instrument played with only the left hand -It can play in a brass or woodwind ensemble -It consists of 12 to 13 feet of metal piping
38 polyethylene piping does not exist.
1- The piping must be supported with clevis hangers with a metal compatible to copper to prevent electrolytic action2- The spacing between hangers must support the piping from sagging or placing stress on the threaded joints
IT IS PART Galvanized don't you knowGalvanized is ZINC coating on black steel and YELLOW BRASS piping is 40% ZINC and 60% Copper and RED BRASS is 85% Copper and 15% Zinc=The problem with TOO much Zinc content is dezincification where the piping becomes brittle and to little zinc and the brass is too soft as the higher copper content.==Mixing Galvanized steel and brass or copper causes a condition of electrolytic action as your mixing ferrous metals and non ferrous metals. ( this is first year apprentice training) to prevent the electrolysis one should use a dielectric fitting=
Red Brass piping schedule 40 with TP copper fittings and brazed joints Ans 2 - PEX piping with brass fittings is far more long lasting and cheaper to install than any copper - ( the above answer could only be from a plumbing company trying to drum up business )
There are only about 5900 piping plovers left in the world.