answersLogoWhite

0


Best Answer

To answer this question the voltage of the motor is needed.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How much kva is required to run a single phase 5hp motor using generator?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What generator is suitable for a 2 HP single phase motor?

Any single-phase a.c. generator producing more than 2.5 HP or 2 kW - at the required voltage.


How do you reverse single phase ac motor to generator?

how reversing an ac single phase induction motor to wark as induction generator


What type of converter is required to act a sedc motor as a generator?

single phase fully control converter


Can a diesel generator for elevators run on single phase?

If the elevator has a single-phase motor, the diesel generator can also be single phase provided the voltage and VA ratings are compatible.


Can you run a three phase motor with single phase generator with help of phase converter?

Terminology gets misapplied but a 3-phase converter produces a 3 phase supply from a single phase supply. The only proviso is that generator, converter and motor are all suitably rated and compatible.


How do you convert or rewire a 20HP 3 phase motor to single phase motor?

The winding design of the motor will not economically allow this to work. You would have to drive a 3 phase generator to supply it.


How many earth wires are required for single phase motor?

There is only one ground wire needed on any motor, single or three phase.


How do you turn a 3 phase motor in to a generator?

We can convert a 3 phase ac motor into generator by changing phase sequence of the ac input cable of that motor


How to build a Rotary phase converter?

A simple Rotary phase converter is just a motor generator set. An electric motor running on the input voltage/current/phase/frequency. it drives a generator that supplies a different voltage/current/phase/frequency. So an electric motor and an electric generator connected together mechanically, either on the same shaft, or via gears, constitutes a Rotary phase converter. the above is incorrect, the motor/generator is the same motor, just one 3 phase motor is needed, it will run on T1 and T2, and put out L1, L2, and L3. You just need to know how to wire it up and what to do to get it to spin over on simple single phase 220, it will create three phase 220.


What would be the horse power required in a 3-phase motor to replace a .5 horsepower single phase motor.?

You still need the same horsepower. The advantage of the three-phase motor is that it will draw lower current.


How does a motor-generator set work?

As the name implies, a motor-generator set utilizes an electric motor as the prime mover to drive a generator. The motor and generator can be mounted on a common shaft or they can be mechanically connected through a coupling, belt drive system or reduction gear.In all cases, the motor requires a source of power (from whichever electrical supply service is available) and it drives the generator to produce the required electrical output power. For instance, if a single-phase supply service is the only service available at a location, the generator's output could be three-phase ac which could be used to supply power to machinery which has three-phase motors, etc.If a site has equipment which requires only direct current the generator could be one that produces dc. That is a less common setup because a full-wave rectifier could easily be used to produce plain dc from ac, but a motor-generator set can still be used for very specialized applications which need highly accurate control of a dc motor under varying load conditions. The Ward Leonard Drive System is a specialized example of such a motor-generator set. (See the Related Link below for more information.)Nowadays, because high-power electronic inverter units are sold to produce a three-phase service from a single-phase service, motor-generator sets are used mainly for very specialized industrial sites, for engineering development and for scientific research applications.It should be noted that there is no need to use a motor-generator set or an inverter unit to produce single phase from three-phase because any one line of a star-connected three-phase service, along with a neutral wire connected to the central star point, can easily be used as a single-phase service.The Related Links below give a lot more information about motor-generator sets.


How does a motor generate?

As the name implies, a motor-generator set utilizes an electric motor as the prime mover to drive a generator. The motor and generator can be mounted on a common shaft or they can be mechanically connected through a coupling, belt drive system or reduction gear.In all cases, the motor requires a source of power (from whichever electrical supply service is available) and it drives the generator to produce the required electrical output power. For instance, if a single-phase supply service is the only service available at a location, the generator's output could be three-phase ac which could be used to supply power to machinery which has three-phase motors, etc.If a site has equipment which requires only direct current the generator could be one that produces dc. That is a less common setup because a full-wave rectifier could easily be used to produce plain dc from ac, but a motor-generator set can still be used for very specialized applications which need highly accurate control of a dc motor under varying load conditions. The Ward Leonard Drive System is a specialized example of such a motor-generator set. (See the Related Link below for more information.)Nowadays, because high-power electronic inverter units are sold to produce a three-phase service from a single-phase service, motor-generator sets are used mainly for very specialized industrial sites, for engineering development and for scientific research applications.It should be noted that there is no need to use a motor-generator set or an inverter unit to produce single phase from three-phase because any one line of a star-connected three-phase service, along with a neutral wire connected to the central star point, can easily be used as a single-phase service.The Related Links below give a lot more information about motor-generator sets.