answersLogoWhite

0

How to convert 166 amp three phase to single value?

Updated: 8/17/2019
User Avatar

Wiki User

11y ago

Best Answer

You can't. Currents in three-phase systems are measured in each of the individual line conductors.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How to convert 166 amp three phase to single value?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How you convert the value of single phase power to value of 3 phase power?

Electric power is measured in watts. It does not matter if it is single phase or three phase. All things being equal, for the same load, the power measured in a single phase circuit or a three phase circuit, will be the same.


How do you convert 380v 3 phase to 220v 3 phase?

Mathematically, just divide 480 by the square root of three. Electrically, 480V refers to the line-to-line value of a three phase system. For example, measure the voltage across A-phase and B-phase and you'll get 480V. 277V is the line-to-neutral value. Measure the voltage across A-phase and the neutral conductor and you should get 277V.


Why is the amperage in single phase double than of 3 phase?

If I have 1 KW In 3 Phase it will give 1.54 A and In single phase it will give 4.6 AFor cosF 0.9V 415 3 phV 240 1 phIt seems the reason is because the current is carried on more wires. Also, remember that if wattage stays constant, then as voltage increases, current decreases.AnswerIt really depends on the load. Are you assumining the three-phase load to be the same as the single-phase load or, as it is likely to be in practice, three times the value of the single-phase load?But, in either case, the single-phase current will not be double the the three-phase (line) current!The equation for the load current supplying a single-phase is: I = P / (E x power factor)The equation for the line current supplying a balanced three-phase system is: IL = P / (1.732 x E x power factor)If you insert real figures into these equations, (240 V for the single-phase voltage and 415 V for the three-phase line voltage) then you will find that, when the three-phase load is threetimes that of the single-phase load, the supply currents will be exactly the same. On the other hand, if you assume that the three-phase load is exactly the same as the single-phase load, then you will find that the three-phase line current will be one-third that of the single-phase current.


What size aluminum wire to feed a 100 amp panel 240 ft away?

To answer this question the voltage value and whether the system is three phase or single phase needs to be given.


Why delta connection is used in load side?

There are a number of advantages why three phase (delta or Y configuration) is preferred over single phase circuit. The best advantage is that the each of the three lines in a three phase circuit can act as single phase thus effectively getting three single phase circuits in one transmission. Another advantage is whether it's single phase or three phase, the generation is the same, therefore three phase has more practical value. Also, the instantaneous power in single phase falls to zero but in three phase system, the net power from all the phases is continuous.


What is peak voltage value of 3 phase?

The same as in single phase with the same RMS voltage.


How do you convert 3 phase power to 2 phase power?

You need to have a properly sized Phase Converter Installed. What do you need 2 phase for? Is it just one piece of equipment? If so it may be is easier and cheaper to convert the equipment.If you are looking for a Licensed electrician you can find one at www.contraxtor.comAnswerDo you really mean a 'two-phase' system? This is an archaic system in which the phase voltages are displaced by 90 electrical degrees. Many people mistake this term for the 'split-phase' system, used in North America, to provide a 240/120-V service. If you do mean a 'split-phase' system, then you will need a single-phase transformer whose primary is connected across any pair of the three-phase line conductors, and a centre-tapped 240-V secondary. The centre tapped connection is earthed (grounded) to provide the neutral connection, and the potential of each end of that winding is 120 V with respect to the neutral. Of course, the turns ratio of your transformer must be appropriate for your three-phase supply. As the original answer indicates, this work will need to be performed by a licensed electrician.


Why floating neutral in a three phase supply is undesirable?

Floating neutral in 3 phase supply is undesirable as if the same thing occurs then there will be bad effect for all single phase equipment which we are using as phase to neutral voltage will exceed from its normal value and it will harm the equipments.


Why does a single phase synchronous motor need a capacitor but for a three phase motor it is not required?

A three-phase motor has a rotating magnetic field inside that is set up by the supply, so the armature always rotates in the correct direction. A single-phase motor can in principle start either way so it has a starting winding supplied through a capacitor to provide a small component of rotating field to get it started the right way. After it has picked up speed the starting winding can be switched out.


What is the voltage value phase to phase at 180 degrees apart?

Single phase voltages vary throughout the world. To answer this question a basic voltage or country voltage has to be stated.


How you determine the starting and running winding of a capacitor start single phase motor?

I think the resistance value of starting winding is less than the running winding of the single phase motor


What is a difference between 3 phase and single phase?

AnswerA single-phase system has two conductors: a line and a neutral.A three-phase system has either three or four conductors. For a three-phase, three-wire, system the conductors are called line conductors. For a three-phase, four-wire, system there are three line conductor and a neutral conductor. In Europe, the three line conductors are coloured brown, black, and grey, and the neutral conductor is coloured blue.