if its a single current its 120v X 25 amp = 3000 watts
Yes, it will be protected by a circuit breaker or fuse. The normal rating of the circuit breaker or fuse is 25% more than the maximum current expected, or the maximum current allowed for the cable size, whichever is lower.
If the appliance is just to be plugged into a circuit with multiple outlets then you just need to make sure that the sum of currents for all devices on the circuit are less than the rated current. A rule of thumb is total current should be no greater than 80% of the rated current. So you might have a 20 A breaker and several 2.5 A appliances on this circuit. If you have a dedicated circuit for the appliance you would only need to size the breaker for the maximum current being drawn by the appliance. If the appliance contained a motor then there might be a start-up current that might be as high as 15 amps so you would likely go to a 20 amp breaker for a safety margin. As a practical matter a dedicated circuit for an appliance in the 2.5 amp range should have a 15 amp breaker. I always install a 20 amp breaker just for added margin and possible future applications.
A circuit breaker does not "cause" smoke. A circuit breaker "breaks" a circuit when there is too much current, creating a hazardous condition for the wires that are connected to the circuit breaker. The circuit breaker PROTECTS you from electrical fire. Find the source of the smoke; what burned? If a circuit breaker tripped during the incident, it is usually caused by melting/burning wire insulation, either inside or outside of an appliance. If the insulation inside the walls of your house has burned/melted, it could be that the circuit breaker was too large for the wire or that the circuit breaker failed to shut off at the appropriate current load. If the circuit breaker failed, your insurance should help you. If an appliance overloaded the circuit, your insurance should help you. If someone connected an oversized circuit breaker, causing the wire to overheat, your insurance company may refuse to help you.
Each appliance has its own amperage. This can be shown by looking at the label of each appliance. A circuit is protected by a breaker which has a trip limit. By continually adding more amperage from different appliances, the circuit becomes overloaded. When the circuits limit is reached because of the additive effect of more appliances to the circuit the breaker will trip. This disconnects the appliance loads from the distribution panel supply and prevents over loading of the conductors of that circuit. Without removing some of the load amperage, the breaker will keep tripping when reset.
A 40A MCB is a circuit breaker. The surge current limit is protected to 250A 8/s0uS. The limitation capability of a circuit breaker is that characteristic whereby a current less then the prospective fault current is allowed to flow under short circuit conditions.
Yes, it will be protected by a circuit breaker or fuse. The normal rating of the circuit breaker or fuse is 25% more than the maximum current expected, or the maximum current allowed for the cable size, whichever is lower.
If the appliance is just to be plugged into a circuit with multiple outlets then you just need to make sure that the sum of currents for all devices on the circuit are less than the rated current. A rule of thumb is total current should be no greater than 80% of the rated current. So you might have a 20 A breaker and several 2.5 A appliances on this circuit. If you have a dedicated circuit for the appliance you would only need to size the breaker for the maximum current being drawn by the appliance. If the appliance contained a motor then there might be a start-up current that might be as high as 15 amps so you would likely go to a 20 amp breaker for a safety margin. As a practical matter a dedicated circuit for an appliance in the 2.5 amp range should have a 15 amp breaker. I always install a 20 amp breaker just for added margin and possible future applications.
A circuit breaker does not "cause" smoke. A circuit breaker "breaks" a circuit when there is too much current, creating a hazardous condition for the wires that are connected to the circuit breaker. The circuit breaker PROTECTS you from electrical fire. Find the source of the smoke; what burned? If a circuit breaker tripped during the incident, it is usually caused by melting/burning wire insulation, either inside or outside of an appliance. If the insulation inside the walls of your house has burned/melted, it could be that the circuit breaker was too large for the wire or that the circuit breaker failed to shut off at the appropriate current load. If the circuit breaker failed, your insurance should help you. If an appliance overloaded the circuit, your insurance should help you. If someone connected an oversized circuit breaker, causing the wire to overheat, your insurance company may refuse to help you.
Each appliance has its own amperage. This can be shown by looking at the label of each appliance. A circuit is protected by a breaker which has a trip limit. By continually adding more amperage from different appliances, the circuit becomes overloaded. When the circuits limit is reached because of the additive effect of more appliances to the circuit the breaker will trip. This disconnects the appliance loads from the distribution panel supply and prevents over loading of the conductors of that circuit. Without removing some of the load amperage, the breaker will keep tripping when reset.
since circuit breaker consists of coils they get heated up when high current flows, when this happens the coil get energised and pull the moving contacts to open thus the circuit breaker opens when high current flows.
A 40A MCB is a circuit breaker. The surge current limit is protected to 250A 8/s0uS. The limitation capability of a circuit breaker is that characteristic whereby a current less then the prospective fault current is allowed to flow under short circuit conditions.
The purpose of a circuit breaker in a panel is to protect the wiring and devices like switches, outlets and other devices that are part of that circuit. It isn't unusual to plug in an appliance into a circuit whose amperage rating is less than the breaker protection. If such an appliance doesn't have its own over-current protection it may well "fry" in an over current situation. However, if your 40 Amp device is directly connect to the 70 A circuit and has no over-current protection on its own you are risking a serious problem. If your 40 A device is on this dedicated circuit you should protect it with a properly sized breaker.
No, a circuit breaker is a safety device that is used in a circuit to limit the amount of current in an overload or short circuit condition. The number on a breaker is the top end current that the breaker will handle before opening the circuit.
A circuit breaker does not give off amperage. A circuit breaker allows a flow of current up to the rating of the breaker. Any current higher than that of the breaker's rating will open the breaker's contacts and stop the flow of current.
yes when combined with a suitable protective relay
The total amps on the circuit exceeds 15 amps. It is possible your appliance is drawing more than 15 amps, but more likely that there are other things on the circuit causing the total current to be exceeded.
the maximum short current that can be safely break by the circuit breaker.