answersLogoWhite

0


Best Answer

Yes! · To accelerate the motor to the rated speed

· To limit the starting current in the armature to a safe value

· To disconnect the motor in case of a supply failure or overload

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Is four point starter is applicable to compound motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is a three point starter?

A three point starter is a device that is meant to help start a DC motor. A three point starter will start device without much starting current.


What dc motor uses a two point faceplate starter?

kn


What is use of two point starter in electrical machines?

Ans- majit khan -we know starter is a safety device. Two point starter is used for Dc series motor. In two point starter all the thing's are connected in series.


Why 3 point starter is called 3 point starter?

Because it has three terminals L , F and A L - Line (connected to Supply) F - Field (connected to field of dc motor) A - Armature (connected to armature of DC motor) that's y it is called 3 point starter :)


Why a DC motor starter is called 3 point starter?

Because it has three terminals L , F and A L - Line (connected to Supply) F - Field (connected to field of dc motor) A - Armature (connected to armature of DC motor) that's y it is called 3 point starter :)


What is the use of 4-point starter in motors?

The four-point starter eliminates the drawback of the three-point starter. In addition to the same three points that were in use with the three-point starter, the other side of the line, L1, is the fourth point brought to the starter when the arm is moved from the "Off" position. The coil of the holding magnet is connected across the line. The holding magnet and starting resistors function identical as in the three-point starter. * The possibility of accidentally opening the field circuit is quite remote. The four-point starter provides the no-voltage protection to the motor. If the power fails, the motor is disconnected from the line.


Want to know about two point starter?

In DC series motor, field and armature are in series. so we use only two points. They are line and armature. therefore we use two point starter.


How do i remove a starter motor from a ford transit van?

To remove the starter from a ford transit van, first you need to disconnect the battery. Once the battery is disconnected, you will find the starter on the gearbox facing the flywheel. At this point, you will need to remove connectors that are located on the back of the starter, and take out the bolts that hold it in place. By giving the starter a shake, the starter motor should come out.


Difference between 3 point starter and 4 point starter?

1." the shunt connection in four point stater is provided separately form the line where as in three point stater it is connected with line which is the drawback in three point starter 2.In three point starter NVR (no voltage relay)is series with shunt if voltage falls certain value NVR De energized due to insufficient magnetic field and motor turned off. But in four point starter NVR energized directly from DC supply thus the draw back of 3 point starter rectified


What is three point dc shunt motor starter?

L , F and A L - Line (connected to Supply) F - Field (connected to field of dc motor) A - Armature (connected to armature of DC motor) that's y it is called 3 point


Is 4 point starter used to start and control the speed of dc shunt motor with armature resistance control?

yes


Why dc series motor need two point starter?

I dont no im a 5 year old child (female)