You have a 3ml syringe and need to give 0.05cc of insulin How much do i draw up in units?

only use a insulin syringe for insulin. insulin MUST be correct.


For injecting insulin which disposable syringe has the finest needle?

The syringes used for insulin administration can be fit with many sizes of needles. The finer needles have a higher gauge number....a 28 gauge needle is bigger/fatter than a 31 gauge needle, which is considered ultra-fine. The size of the syringe depends on the amount of insulin to be injected.


If you use a 1 ml insulin syringe how many units would you draw up?

In a 1 mL insulin syringe, the markings typically represent units of insulin, not milliliters. The number of units you would draw up in a 1 mL insulin syringe depends on the concentration of the insulin you are using. Common insulin concentrations are 100 units/mL and 50 units/mL. If you are using insulin with a concentration of 100 units/mL and you want to draw up a certain number of units, you simply draw up that number of units on the syringe. For example, if you want to draw up 10 units of insulin, you would fill the syringe to the 10 unit mark on the syringe. If you are using insulin with a concentration of 50 units/mL, then each unit on the syringe represents 2 units of insulin. So, to draw up 10 units of insulin in this case, you would fill the syringe to the 5 unit mark. Always make sure to use the correct insulin concentration and syringe to accurately measure and administer your insulin dose. If you are unsure about the concentration or how to use the syringe, it's important to consult with a healthcare professional or pharmacist for guidance.


Does Dropping a syringe full of insulin ruin the syringe?

it dose because it is not sterial any more


What is the use for an insulin syringe?

The insulin syringe is marked in units of insulin. In the US most (I don't know if there is any other still distributed in US) insulin is U-100. U-100 will have 100 units per mL.So if you take 50 units of U-100 insulin, you are taking 1/2 mL. The syringe makes iteasy to take the number of units you need, with the needle made so the insulin won't clog in it, yet glide in easily into the skin. The insulin syringe is made to deliver the insulin dose just under the skin (subcutaneous) NOT into the muscle.


What is the difference between a tuberculin syringe and an insulin syringe -?

They are made for administration of specific measurements of either insulin or the antigen for TB testing called PPD (Purified Protein Derivative). Both types of syringes are calibrated into "units". Unit measurements are fixed measures but specific to each type of medicine/solution as to their volume. A unit of insulin is not the same thing as a unit of TB antigen, so the TB syringe can not be used in the place of an insulin syringe. Insulin is administered with the insulin syringe "subcutaneously" (under the skin) in the subcutaneous (sub Q) tissue. The needle is slightly longer than that on a TB syringe. The antigen solution is administered in the TB test "intradermally" (within the skin/between the layers of the skin) instead of under the skin, so the needle is shorter. The amount of liquid in a dose of TB antigen is much smaller than the amount usually given of insulin. Therefore, the barrel of the TB syringe is smaller in diameter to allow such very small amounts (drops) of antigen to be measured. In addition, insulin syringes come in two scales of measurement: U-100 and U-40. This on the label of the syringes indicates which type of insulin they are made to measure and administer. The insulin vial will also be marked either "U-100" or "U-40". One strength is 100 units of insulin per mL and the other is 40 units of insulin per mL. A different insulin syringe is need to measure U-100 than the type used to measure U-40. Unit calibration on the syringe used must be matched to the "strength" of the insulin being used. U-100 insulin has 1/100 of a mL volume per unit (equal also to 1/100 of a cc). U-40 insulin has 1/40 of a mL volume per unit.


30 unit of 40 iu insulin is equal to how much unit of 100 iu insulin?

IU is international units and it's same whether it's of 40 IU or 100 IU insulin. But one is supposed to use 40 iu syringe for 40 IU and 100 IU syringe for 100 IU insulin. You take 30 units in corresponding syringe, dose is gonna remain same. If you interchange the syringe then things get complicated and need to do some math. So for 30 units of 40 IU insulin and want to use 100 IU/ml syringe then you need to use 75 units of 40 IU in 100 IU syringe. Avoid interchange of syringe to be safe.


What is the omni pod?

An omnipod or An insulin pump is a medical device used for the administration of insulin in the treatment of diabetes mellitus, also known as continuous subcutaneous insulin infusion therapy. The device includes: * the pump itself (including controls, processing module, and batteries) * a disposable reservoir for insulin (inside the pump) * a disposable infusion set, including a cannula for subcutaneous insertion (under the skin) and a tubing system to interface the insulin reservoir to the cannula. An insulin pump is an alternative to multiple daily injections of insulin by insulin syringe or an insulin pen and allows for intensive insulin therapy when used in conjunction with blood glucose monitoring and carb counting. A celeb such as Nick Jonas uses this as soon as he found out he had diabetes


Can i buy syringe in walgreen?

if you have an insulin or other needle-needing prescription there


How many cc does a insulen needle hold?

I think that you are referring to the insulin syringe,not the needle. The standard insulin syringe holds one cc, divided into 100ths, which is equal to one UNIT of insulin. It is imperative that you are using a U100 insulin solution with a U100 syringe. If you don't, the incorrect dosage could be catastrophic. There are some smaller insulin syringes that only hold 0.5 cc (making them half the size of the 1cc). They are STILL marked properly for U100 insulin even though they are smaller in size. Hope that this helps!!clkfrau1@aol.com


Why cant you mix insulin into food instead of injecting?

If you put insulin into food it would not have the same effect. You see, insulin needs to be in the blood stream. That is why you have to inject it with a syringe.


What is the difference of tuberculin to insulin syringe in terms of measurements?

They are made for administration of specific measurements of either insulin or the antigen for TB testing called PPD (Purified Protein Derivative). Both types of syringes are calibrated into "units". Unit measurements are fixed measures but specific to each type of medicine/solution as to their volume. A unit of insulin is not the same thing as a unit of TB antigen, so the TB syringe can not be used in the place of an insulin syringe. Insulin is administered with the insulin syringe "subcutaneously" (under the skin) in the subcutaneous (sub Q) tissue. The needle is slightly longer than that on a TB syringe. The antigen solution is administered in the TB test "intradermally" (within the skin/between the layers of the skin) instead of under the skin, so the needle is shorter. The amount of liquid in a dose of TB antigen is much smaller than the amount usually given of insulin. Therefore, the barrel of the TB syringe is smaller in diameter to allow such very small amounts (drops) of antigen to be measured. In addition, insulin syringes come in two scales of measurement: U-100 and U-40. This on the label of the syringes indicates which type of insulin they are made to measure and administer. The insulin vial will also be marked either "U-100" or "U-40". One strength is 100 units of insulin per mL and the other is 40 units of insulin per mL. A different insulin syringe is need to measure U-100 than the type used to measure U-40. Unit calibration on the syringe used must be matched to the "strength" of the insulin being used. U-100 insulin has 1/100 of a mL volume per unit (equal also to 1/100 of a cc). U-40 insulin has 1/40 of a mL volume per unit.