No, brass cannot be used as a dielectric union between copper and black iron pipe. Dielectric unions are typically made of materials that are not electrically conductive, such as plastic or rubber. Brass is a conductive material and would not provide insulation against galvanic corrosion between copper and black iron pipe.
a megger or hipot test involves raising the voltage of the wiring to 2x the operating voltage + 1000v answer volts/amps or ohms Dielectric test usually a sample of the oil is taken from the transformer answer is in ohm-cm dry devices will have the dielectric tests on file ... this is a very poor excuse ... the code need rewriting. the old standards were based on porcelain, oil, paper and cotton AI MI SWC DWC new types THN THWN THHN SO are generally based on a natural color when the tests are done so if you replace a cord on a drill the white and green wire has insulation that crumbles while the black is still flexable. thermoplastic insulation used for several years in damp locations with DC turns to a sticky goo.
black patent is the really shiny one, whereas the black pu is the dull, unshiny looking one
From: http://goliath.ecnext.com/coms2/gi_0199-171383/Carbon-black-measures-up-in.html P-type carbon black is one that satisfies all specifications required for pressure-pipe applications to meet worldwide industry standards:
Abs to PVC glue sold at home depot Color it aqua blue/green plumbers key term. GUMBY GLUE Depends upon what you mean by "black pipe". If you mean ABS drain pipe, there is glue for that. If you mean steel "black pipe", i.e., non-galvanized, then you would need a threaded connection adapted to the PVC (either a female PVC connector on a male black pipe or a male PVC connector into a female black pipe fitting). The secondary question would be, "Why would anyone want do to that?"
Yes, need one between the two dissimilar metals.
Brass and steel are compatible, Otherwise we could NOT use brass valves with steel piping.
No, brass cannot be used as a dielectric union between copper and black iron pipe. Dielectric unions are typically made of materials that are not electrically conductive, such as plastic or rubber. Brass is a conductive material and would not provide insulation against galvanic corrosion between copper and black iron pipe.
Yes
Certainly, if the pipes are kept dry, and don't carry an electrolyte, such as water.Otherwise, it's a bad idea to directly connect different metallic pipes. In fact, most plumbing codes prohibit such a connection.That's because anytime any two dissimilar metals contact each other -- while in the presence of an electrolyte -- whichever metal has the higher electropotential will corrode, through electrolytic action.So, in the case of copper vs iron, the copper side of the joint will eventually fail due to corrosion -- unless you electrically isolate the two metals.You can do this via a dielectric union, or dielectric nipple. Or, you can use a hardened brass fitting, which resists corrosion and also smooths the dielectric potential between the copper and steel.Of course, another author may have a different opinion (like the one below.) So my advice is to understand the 'why' of electrolytic corrosion, so you can determine whether or not, in your case, a dielectric union is advisable.####Of course , NO Problem and there are many ,many options of doing so.The electrolytic conditions happens when connecting ferrous metals to non ferrous metals that contain zinc (galvanized) if you think about it EVERY SINGLE CAST IRON RADIATOR has a brass shut off valve, Most black steel gas line have a BRASS gas valve. Brass bolts are the best way to go when installing CAST IRON ROOF DRAINSAlso why use a dielectric union when there are dielectric nipples less chance of leakage
it is the mechanical -carpentry,fitting,black smithy,house wiring,welding
Between the speedometer and the fuel tank, there is a black fitting that you can unscrew by hand. It looks like part of the tank hold-down, but that's actually your dipstick!
Black plastic pipe is ABS -Use yellow ABS cement. -I don't understand "grey bard fitting" -Take this to your plumbing store and they will advise.Black plastic pipe is ABS -Use yellow ABS cement. -I don't understand "grey bard fitting" -Take this to your plumbing store and they will advise.
Brass is normally used for the gas connector to an appliance and for small shut off valves Piping and related fittings black steel is used ABOVE Ground in on piping not exposed to excessive moisture
Wear black, loose fitting clothing. Not too loose or it will look sloppy.
They required segregation in public places between African Americans and others in the United States.
You get your white belt when you first start (No grading session required)Then instructor awards you yellow tip (Again no grading session required)Then yellow (Grading session required)Then orange tip (No grading session required)Then orange (Grading required)Then green ( Grading required )Then blue ( Grading required )Then red (Grading required )Then brown (Grading required)Then black tip (Grading required)A second black tip (Grading required )Then black (Grading required)