Best Answer

It depends on the source impedance. This is very often not true.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Is line to line fault is larger than line to ground or double line to ground fault?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What are the types of faults in ehv transmission lines?

The three types are Line to ground faults line to line fault double line to ground fault three phase line to ground fault


What are the types of transmission line faults?

these are the faults that occur in transmission line: 1. line to line fault 2. line to ground fault-this is the most common fault that occurs in tr. line(75%) 3. double line to ground fault 4. triple line to ground (or) 3 phase fault- this is the most serious and dangerous fault that occurs in transmission line.(but rarely occurs)


What is phase to ground fault?

There will a only one phase on home electricity.AnswerThere is no such thing as a phase-to-phase-to-ground fault'; the correct term is 'line-to-line-to-ground fault. It occurs when two or more line conductors make contact with each other and to ground; for example, when a JCB accidentally cuts through a three-phase cable.


The place under the ground where the earthquake originates?

That is a fault line.


Is the fault line on the east coast larger than the west coast?

No


Is it advisable to use line to neutral power supply on a single phase residential area when the safety is concern?

line to line or line to neutral is the only way to use power line to ground if a FAULT current in the ground is a problem that needs to be corrected, an insulation fault


Do earthquakes start under the sea or ground?

either. depends on where the fault line is


What is a foot fault?

A foot fault is when you serve and your foot touches the ground on or or forward of the service line before you strike the ball.


What is neutral to ground fault?

Neutral, by definition, is grounded at the distribution panel, and also at the distribution pole. That is how the hot to ground voltages are prevented from exceeding their normal voltage and encroaching on truly lethal voltages, such as 7.6kV in a typical US 13.2kV system, in a wye configuration.Note: and this is critical, do not depend on the fact that neutral is grounded and consider that it is the same as protective earth ground. It is not. Protective earth ground is a different wire.


3 types of faults?

Reverse faultNormal faultStrike-slip fault


When a tree falls on power lines grid what fault is it?

It depends on what happens. It could cause adjacent conductors to clash (line-to-line short-circuit fault), or it could break a conductor which then makes contact with the ground (line-to-earth short-circuit fault), or it could be neither of these.


Has San Andreas been hit by an earthquake?

Yes San Andreas has had an earthquake in fact it has been a lot of them San Andreas even has a fault line named after it (The San Andreas fault line is actually a visible crack in the ground) and a lot of earth quakes happen upon a fault line.