Answer for USA, Canada and countries running a 60 Hertz supply service.

Yes, the neutral is connected to a system ground in the main distribution panel.

User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

Can the ground and neutral wires be connected to the same bar in the main panel?

No, the ground and neutral wires should not be connected to the same bar in the main panel. It is important to keep them separate to ensure proper functioning of the electrical system and to prevent potential safety hazards.


Why dont you use earth wire place of neutral?

Earth is neutral, but only at the distribution panel and upstream from it. Downstream of the distribution panel, earth and neutral shall not interchange or cross connect their connections or their roles - earth is protective ground - and neutral the current carrying return conductor.


Where do you hook your neutral in your breaker panel if there is no neutral bar?

Unless the panel is the Main Panel (first panel in the system after the service feed) all panels have a neutral bar. Otherwise you are missing pieces. If this is the Main Panel, the neutral bar is bonded to the ground by a bus-bar. If this is the case, neutrals should all be connected to the same side of these bonded bars. Electrically it makes no difference, however it is a good practice to keep electrical panels neat and organized. If this is not the Main Panel and there is no neutral bar, STOP, PUT DOWN THE TOOLS, CALL A PROFESSIONAL. This panel is missing pieces and may be dangerous. It is possible to have a panel without a neutral. This panel would serve only 240 volt loads where no neutral is needed, however I have not seen this done in residential applications.


Where is the main switch connected?

the main switch is connected in the center of the panel


In the typical home electrical panel installation the main ground wire is connected directly from a ground rod driven into the ground to the?

In North American residential homes, there are 3 wires coming from the utility company, two "hots" and neutral. The two "hot" conductors get connected to the main breaker. The neutral gets connected to the neutral bus bars located along the sides of the breaker box. There is a set screw that is placed in the neutral bar that screws into the distribution panel enclosure thereby bringing the potential of the neutral bars down to zero. The wire from your ground rod is also connected to the neutral bus bar, and thereby it is connected to the neutral from the power company. This is also often bonded to the copper cold water plumbing in the house if the home is not plumbed in PVC water pipe. White circuit wires are then connected to the neutral bus bars. Also in the distribution panel are ground bus bars. The ground wires from circuit cables are connected to these grounding bars. Do not under any circumstance terminate the white and bare ground wires together. Ground wires to the ground bar and white wires to the neutral bar.


Can you have a neutral and common buss bars in a junction box that is connected to main panel?

Yes, you can have neutral and common bus bars in a junction box connected to the main panel, but they must be kept separate to comply with electrical codes. The neutral bus bar should only connect to neutral wires, while the common or ground bus bar should be dedicated to ground wires. This separation helps ensure safety and prevents unwanted current from flowing on grounding conductors. Always check local codes and regulations to ensure compliance.


Why do you isolate the neutral?

If you are working with a sub panel, there are a few reasons to isolate the neutral. Firstly, currents will then return to the main panel and service ground.


Could anybody help the reading between earth and neutral in the incomer supplying power to the house is 120V while live and neutral reads normal 220V and live-earth reads up to 298V.?

It sounds like either you have a bad ground connection or that ground and neutral are NOT bonded at the main panel only. There is either a strap or screw in main panel that connects ground and neutral. Also check the connection to a ground rod and that the ground rod is intact.


In typical home electrical panel installation the main ground wire is connected directly from a ground rod driven into the ground to the?

In North American residential homes, there are 3 wires coming from the utility company, two "hots" and neutral. The two "hot" conductors get connected to the main breaker. The neutral gets connected to the neutral bus bars located along the sides of the breaker box. There is a set screw that is placed in the neutral bar that screws into the distribution panel enclosure thereby bringing the potential of the neutral bars down to zero. The wire from your ground rod is also connected to the neutral bus bar, and thereby it is connected to the neutral from the power company. This is also often bonded to the copper cold water Plumbing in the house if the home is not plumbed in PVC water pipe. White circuit wires are then connected to the neutral bus bars. Also in the distribution panel are ground bus bars. The ground wires from circuit cables are connected to these grounding bars. Do not under any circumstance terminate the white and bare ground wires together. Ground wires to the ground bar and white wires to the neutral bar.


In a typical home electrical panel installation the main ground wire is connected directly from a ground rod driven into ground to the 1 case of the panel or 2 main breaker switch or 3 l?

The main ground wire in a typical home electrical panel installation is usually connected directly from a ground rod driven into the ground to the case of the panel. This helps to ensure that the panel is properly grounded to prevent electrical shocks and provide a safe path for electricity to follow in case of a fault.


Can you tie the neutral wire on a sub feed to another panel to the main neutral lug?

No, the neutral wires from different panels should not be tied together at the main neutral lug. Each panel should have its own separate neutral connection to the main service panel to ensure proper grounding and to prevent potential hazards such as ground faults. Mixing neutral wiring from different panels can cause electrical imbalances and safety issues.


The what of an electrical plug connects the metal to the ground?

The rounded third prong goes to earth ground at the main panel where the neutral is also bonded to ground.