answersLogoWhite

0

Is transformer side interchangeable

User Avatar

Anonymous

13y ago
Updated: 8/20/2019

yes,we can change the transformer side in transmission line as use of high current or high voltage in output.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

Why you uluminium on primary side of transformer?

This isn't the case. You can have aluminium or copper on primary or secondary side of a transformer.


What the purpose of the H1 terminal on a transformer?

The terminals H1 and H2 an a transformer indicate the primary side of the transformer. The secondary side is usually identified as X1 and X2.


What happens to the current as the voltage is increased by the step up transformer?

Compare a transformer to a balancing act. Both side need to remain equal.The primary side of the transformer is the supply side and the load is connected to the secondary side of the transformer.The load governs the current of the secondary side of the transformer and the voltage of the secondary side must match the voltage that the load required to operate.The ratio of the transformer will determine what the voltage of the secondary side is as compared to the voltage that has to be applied to the primary.The current of a step up transformer will be higher on the primary side that that of the secondary.Apply voltage and current to this concept and you will see that the transformer will remain balanced.The size of the transformer is always calculated from the secondary side of the transformer and the value is written in VA or KVA where V = voltage and A = amperage. Power factor is also taken into consideration when calculating the size of the transformer to be used.


Does the fuse on the primary side of a transformer protect the secondary side?

Yes, but it's usual to have fuses on both sides of the transformer.


If a dc voltage of 12v is added to the secondary of step down transformer and rating of transformer is 220 input and 12v output what will be the result from primary of transformer?

Adding a DC voltage to the secondary of a transformer will not have an effect on the primary side, as transformers work on the principle of electromagnetic induction which is based on alternating current. The primary side of the transformer will still operate based on the input AC voltage of 220V. The DC voltage on the secondary side will not be transferred to the primary side.


What is the difference between an isolation transformer and distribution transformer?

in isolation transformer earthing is not provide on secondary side but in ordinary transformer neutral of secondary side is earthedAnswerAn isolation transformer is a 1:1 ratio transformer; its function is to electrically isolate the secondary side from the primary side without changing the voltage. An example of an isolation transformer is the one used in a shaver socket.A distribution transformer is a step-down transformer, used within the electricity network's distribution system. An example of distribution transformer is a pole-mounted transformer, supplying low voltage to residences.(Of course, all mutual transformers provide electrical isolation between primary and secondary.)


What wires conductors would go under x lug in a transformer?

The primary side of a transformer is identified as the H side, eg. H1,H2,H3,H4. The secondary side of a transformer is identified as the X side. Eg. X1, X2. Usually X1 goes to a fuse and then to the load, X2 is usually the neutral side and is grounded to the body of the transformer.


What are the side-effects from transformer oil?

side effects from leaking transformer oils in the early 1970's. Heart, kidney diseases?


Which side of a transformer is the load connected to?

It is connected to the secondary side.


What is the load side of a transformer?

The load side of a transformer feeds the device, such as a light or motor. It is the output of the transformer. The input, or line side, provides the voltage that is to be transformed, either up or down, to supply the load side.AnswerA transformer's primary winding is connected to the supply voltage, and the secondary winding is connected to the load.


What is the different between et up and set down transformer?

the difference between a step up transformer and a step down transformer is that, in a tsep up transformer, the voltage secondary is greater than the primary side but in a step down transformer, the voltage secondary is lesser than the primary side


How does a step-down transformer work?

well the working of the step doen transformer depends on the number of turns on the secondary side of the transformer, now in the case of a step down transformer, the number of turns in the secondary windings are less as compared to the number of turns at the primary side/winding, so the amount of flux which links the secondary side of the transformer is also less resulting in the production of less amount of emf at the secondary side. hence the status of the voltage is decreased as compared to the voltage of the primary side.