If you replaced the furnace and thermostat this past winter, and now the A/C doesn't work. You probably just have a loose control wire. Check the yellow wire at the stat. It should be on the Y terminal. Next, look inside the furnace at the terminal block. The condenser wire should have two conductors. One hooks up with the yellow wire on the Y terminal of the terminal block. The other hooks to the C terminal. Always turn off the breaker to the furnace before working on any wiring. No need to fry the transformer.
air conditorner doesnt blow cold air has freeon compressor doesnt kick on
If compressor is running 80-100% of time without recycling, it may still be low on freon. If freon pressure is good, may be expansion valve.
Depends on what type of furnace you have but it sounds like 1.a wire from the thermostat is shorted, 2.the thermostat is stuck itself or 3. the main gas valve is stuck. Try turning the power off to the furnace next disconnect the wires leading to the gas valve if this stops it check 1 and two if this doesnt stop it then it is number 3
It doesnt
it breaks. like mine has been for the past three years. therefore, the a/c doesnt work and it needs to be replaced. i love it. the transmission also enjoys to die.
Typical causes of a compressor not running are: low coolant, blown fuse in compressor circuit, bad compressor, bad temperature sensor.
The ac may have been discharged during the swap causing it not to work. Also make sure all the electrical plug in connections are clean and properly plugged in including the ac compressor, all engine sensors and radiator cooling fans and relays. Double check the fuses also.
It vents directly out the side of the house n doesnt need a chimney
http://www.kick-fix.com/air-conditioning.html
The compressor is coming on because you have the heater set to defrost. Take it off defrost and the compressor will not come on. I would suspect the compressor is locked up.
Replace the thermostat.
could be a sticking thermostat.