Q: The typical temperature difference between the entering air and the boiling refrigerant on a standard air-conditioning evaporator is?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is chiller approach temperature?

Evaporator Approach is the difference between the evaporating refrigerant temperature - measured at the well in the evaporator -and leaving chilled water temperature.Take all readings with the water cooled chiller at full load.Condenser Approach is the difference between the liquid refrigerant temperature - as measured on the liquid line - and leaving condenser water temperature.


What is a chiller approach temperature?

Evaporator Approach is the difference between the evaporating refrigerant temperature - measured at the well in the evaporator -and leaving chilled water temperature.Take all readings with the water cooled chiller at full load.Condenser Approach is the difference between the liquid refrigerant temperature - as measured on the liquid line - and leaving condenser water temperature.


What causes low evaporator refrigerant temperature on air conditioner?

gas leakage


If the evaporator outlet temperature on a r-410a system is 50p and the evaporator superheat is 10p, what is the evaporating pressure of the refrigerant in this system?

8.2


4 major components of refrigeration and airconditioning?

Compressor, Condenser, Meter Device and Evaporator


What role does a compessor play in a refrigeration system?

In vapour compressor refrigeration system the low pressure and temperature vapour refrigerant from evaporator is compressed. where it is compressed to a high pressure and temperature. From compressor refrigerant goes to condenser where where it changes the phase. from condenser refrigerant goes to evaporator through expansion device.


Where does the refrigerant go when it leaves the evaporator?

The evaporator


Where in the refrigeration system is heat absorbed into the refrigerant?

The heat is released by heat exchangers in the atmosphere.


What is the difference between the dry or direct expansion type of evaporator to the Flooded type evaporator?

Evaporator is said to be flooded type if liquid refrigerant covers the entire heat transfer surface. This type of evaporator uses a float type of expansion valve. An evaporator is called dry type when a portion of the evaporator is used for superheating the refrigerant vapour after its evaporation.


Dry expansion evaporator?

In dray expansion evaporator, the liquid refrigerant is generally fed by an expansion valve. the expansion valve controls the rate of flow of refrigerant to the evaporator. In the evaporator the liquid refrigerant is vaporized and superheated by the time it reaches to the end of evaporator. At inlet of the evaporator, the refrigerant is predominantly in the liquid form with a small amount of vapor formed as a result of flashing at the expansion valve. the liquid refrigerant passes through the evaporator, more and more refrigerant is vaporized by the load. according to the load, the liquid will come into evaporator and vaporize and reaches to superheat at the end of the evaporator. The inside of the evaporator is far from dry but wetted with liquid so named as dry expansion evaporator.


How does an evaporator work?

an evaporator is a part of a refrigeration plant by which the refrigerant is made to boil at a much lower temperature and pressure. the idea is to extract the heat from the region which we want to cool. basically the evaporator is located at the region where the thing to be cooled is situated.


What trouble may be indicated by a warm evaporator line?

I'm just a student of HVACR and I think a lack of refrigerant will be indicated by a warm an evaporator or the outlet end of the evaporator.