short answer: Only people with and EPA certification may purchase R22 and/or R410A refrigerants.


What gas is used in air conditioner?

As of now, Air conditioner uses R22 refrigerant. In coming days ACs will come with refrigerants such as R410A, R407C etc.


Explain what Refrigeration Compatibility means in relation to refrigeration oils?

There are different types of refrigerant oils. Refrigerants such as R22 and R12 usually use mineral oil. But some of blended refrigerants like R410A can sometimes use a poly oil. These oils can not be blended together. So a system that already has a refrigerant with mineral oil must be charged with refrigerants with the same oil.


Do home air conditioners use the same refrigerants as those in cars?

No. They use R22 or R410A. Cars use R12 (before 1993) and R134A (after 1993). You cannot mix them together.


Can you mix r134a with r410a?

Can you mix r134a with r410a?


Can a R410A evaporator be used with a R22 condensor?

No, R410a runs higher pressures.


Can a R410A condensor be used with a R22 evaporator coil?

No, R410a runs higher pressures.


Why are there more safety precautions with r410a than with other popular refrigerants like r22 and r404a?

The pressure of R-410A is significantly higher than other refrigerants R-22 and R-404A. This does not mean that R-410A, or equipment containing R-410A is unsafe. It does mean that technicians must use AC equipment; cylinders and service tools have been re-engineered to handle these higher pressures.


Is R410a freon compatible with R22?

No


Can you use a r410a condenser brand new with a r22 air handler brand new?

No. r410a runs at a much higher pressure.


What licence do you need to buy r-22 or r410a refrigerant?

R22 needs import license,R410A does not need anything special


Will a new r22 coil work with 410 refrigerant?

An R22 coil will work properly with R410A only ifseveral conditions are met.First, the manufacturer of the coil must specify that it will work with both refrigerants. R410A systems operate at about 40 to 70 % higher pressure than R22 systems.Second, the new coil must be equipped with an inlet control (either a thermal expansion valve or orifice) that is intended for R410A. The new coil may not use a capillary tube metering system to control refrigerant flow into the evaporator coils.Third, the tonnage, or Btu capacity, of the coil and control device, and the EER/SEER of the coil must match those same ratings for the condensing unit.Fourth, if the new coil has been used in an R22 system, it must be thoroughly flushed clean of oil, and must be refitted with the proper control valving for R410A.