Normally as per IS 8623 There are 3 Test conducted in Type Testing Lab i.e,CPRI Bhopal and Bangalore,ERDA in vadodara. That are short circuit withstand test,Ingress protection Test and Heat Run test or Temperature rise test.
regards
Ramesh 09323586413
Dielectric Strength of Vacuum is more than that of Air. In HT voltage is more than LT. So VCB is used in HT & ACB in LT. Rakesh Gaikwad
to reduce Current and Coast
Frist putt of the main incomer HT side then Rack out the breaker and put the LOTO after that Discharge the cable Both side (HT/LT).
HT drives are the pumps or motors operate at more power typically more than 0.5 Amps at 110 or 220 V DC whereas LT drives operate at lesser power less than 0.5 Amps at 24 V DC or 240 V AC.
For LT cable 1. Use : Up to 690V 2. Insulation : PVC 3. Core(Neutral) : Yes 4. Insulation Grading : 1100 V For HT cable 1. Use : Above 690 2. Insulation : XLPE 3. Core(Neutral) : No 4. Insulation Grading : Above 3.3kV, 11KV..etc ( Please note that now 690 V using in VFD application with LV cable and 440 V for DOT motor starter) from Kunal Singh Dabi the_dabi@rediffmaill.com
The different testing steps of HT and LT panel include commissioning, sanctioning, erection and the CPP set. All this is done in the servicing of the transformers and the HT/LT control panels.
An LT panel is a device that receives power and distributes it to other devices and boards. An HT panel is the same thing except it is used for high tension cables.
LT motor abbrevation
lt pannel is a iow tensan pannel. lt pannel work is 240v and 440v. ht pannel is a high tensan pannel . ht pannel work is 11kv,33 kv ,66kv, 120kv
It's the voltage: HT high voltage LT low voltage Tension = voltage (French?)
Dielectric Strength of Vacuum is more than that of Air. In HT voltage is more than LT. So VCB is used in HT & ACB in LT. Rakesh Gaikwad
The 1999, 2000, 2001 C70 engines that are HT are the 2.4 L Engines. The LT engine is the 2.3 L but it produces more horsepower than the HT.
lt panel is low tension panel... its work is take power from the source and distribute it in a system
ht motor is to be fed with more than 415v like in kvolts. all the other operated below 415 volts are lt motors
if electrical panel is labeled LT, usually means its a lighting panel LT means "Low Tension" panel. Not lighting. Lighting panels are normally known as LDB (lighting Distribution boards)
lt oanel is low tension panel... its work is take power from the source and distribute it in a system
to reduce Current and Coast