Easier to start up. Running remains the same unless it is equipped with a run capacitor too. A run capacitor uses a little less current during run and probably runs a little cooler too.
I think the resistance value of starting winding is less than the running winding of the single phase motor
Firing as in starting and running, no.
Motor used in Table Fan is Split phase Motor(Continuous Running with Capacitor).It has Two winding Running coil + Starting Coil. Running coil connected Direct to Supply Starting coil Connected is series with capacitor than parallel with power.
When you first turn on a motor it is starting from a static position and more current is required to get the motor up to speed (Starting current) than to keep it running (running current). Since watts equals amps times voltage you can see the difference in wattage is related to current. If you look at watts as work being done it is obvious that it requires more work to get the motor running than to keep it running.
There are 2 types of capacitor including starting capacitor and running capacitor running capacitor are used to improve the power factor of motor. starting capacitor used in split phase induction motor . starting capacitor may isolate from motor,s starting winding through of centrifugal switch after getting motor 90% of it,s rated speed.
No.
depending on kva class of the motor between 4-8 times the running current
A starting cap is placed in circuit of the start windings only when the motor is starting and is normally of a higher capacitance than a running cap, in the region of 70 - 120 mf, where a running cap stay connected with the start windings of the motor and is normally an 8 mf cap.
To create rotating magnetic field inside motor stator and it is done by capacitor. current drawn by motor running winding is lagging in nature when capacitor is connected in series with starting winding then the phase angle of running winding current and starting winding currents changes which creates a rotating magnetic field and motor is able to run.
32 poles
Single-phase motors - These motors are commonly fractional-horsepower types, though integral sizes are generally available to 10 hp. The most common single phase motor types are shaded pole, split phase, capacitorstart, and permanent split capacitor.Figure 5 - Rings in shaded-pole motor distort alternating field sufficiently to cause rotation.Figure 6 - Split-phase windings in a twopole motor. Starting winding and running winding are 90 ° apart.Figure 7 - Split-phase start induction motor.
The start up current should be listed on the motor nameplate as FLA , full load amps.