No, the liquid (discharge) line is the high pressure side. The suction line is the low pressure side.
blocked condenser
Low airflow, low refrigerant or restriction
The pressure should be equal to a saturated suction temperature of around 40*F. The pressure would differ depending on which refrigerant is used.
Answer: The terms suction and discharge are the terms refer to hydraulics. In hydraulics if the the liquid has to be lifted or pumped to the usage area the hydraulic pump will be used . This pump will have to functions that is first suction to lift the fluid and the discharge or delivery . The familiar words in pair are lift and discharge; suction and discharge. The specification of pump for these terms are suction head and discharge head.AnswerThe suction pressure refers to the pressure of the referigerant being "sucked" back into the compressor. The suction pressure is a critical variable in ensuring the accuracy of the refrigerant charge, along with the tepmerature of that line as well. The "superheat", or heat added to the vapor in that line can be monitored in this manner.You have not mention which suction pressure... Actually Where ever the suction is presented that pressure is called suction pressure.... and suction pressure in practical cases normally always less that atmospheric pressure and in case of delivery pressure it is oppositeSaying that suction pressure is " the pressure of the referigerant being "sucked" back into the compressor " is not accurate.Simply , the suction pressure of a pump is the absolute pressure of a fluid , measured at the inlet of the pump ( in your answer , the pump is the compressor , and the fluid is whatever refrigerant. )The discharge pressure , is the absolute pressure of the liquid measured at the outlet of the pump.Obviously, the discharge pressure is usually bigger than suction pressure.
At very low suction pressure, the suction valves of reciprocating compressor will not work and there will be no gas in the cylinder during compression stroke, resulting some damage to the suction valves. If low suction pressure trip protection is not provided there can be some abnormal damage.
Suction is caused by an are of negative pressure.
No, the liquid (discharge) line is the high pressure side. The suction line is the low pressure side.
No not always.
Low side.
blocked condenser
Defective pressure switch not cutting out on hi-head pressure The compressor depends on the suction line for coolong the motor, if its low on freon then the suction line will not be cool enough to cool motor windings.
Low and high pressure systems. Obviously if you have a Low pressure system the barometric pressure will get low. High pressure causes the barometric pressure to rise.
High head pressure; low suction pressure; overheated compressor
on the large ref line (suction line)
Air has a pressure, but not a suction pressure. Air pressure is measured with a barometer, you do not calculate it. Suction pressure is a concept which applies to a pump. Suction pressure = static pressure + surface pressure - vapour pressure - friction pressure.
The low pressure switch is usually on either the h valve, accumulator, or in the suction line.