answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What gauge 6' extension cord for 15 amp treadmill?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you make a 30 amp to 15 amp extension cord?

If your extension cord is truly a 30 amp cord then it is composed of #10 wire. #10 wire is rated at 30 amps. All you have to do is remove the 30 amp plug and receptacle ends from the cord and install 15 amp cord ends.


Can you put an extension cord on a treadmill 20 amp?

Make sure the wire size of extension cord is AWG 12 or AWG 10. Also circuit must support the 20A at main panel. Standard household extension cords are usually AWG 14 which are not sufficient to carry 20A.


Can a 15 amp extension cord be plugged into a 20 amp breaker?

A 15 Amp extension cord can be plugged into a 20 Amp circuit. It is important that what you're extending does not require more then 10-12 Amps.


Can you use 6 gauge wire on A extension cord and put 30 amp plugs on it?

If your question is can you use a #6 flexible SOOW cord and put a 30 amp plug on it, then yes. The breaker that feeds the receptacle that the cord will plug into can be no larger than a 30 amp breaker. What limits the cord capacity to 30 amps is the ratings of the plug on the end of the cord.


A gauge 14 extension cord can safely carry 15 A What will happen if several appliances drawing a total current of 18 A will be connected to it?

A 14 gauge extension cord can safely carry 15 amps, but not very far. Number 14 gauge extension cords are only rated for about 13 amps according to the labels on the cord. This is because the insulation is not intended to withstand the heat of currents above this level. Running this cord over 50 feet or loading it to 18 amps would be unacceptable.The likelihood of the cord maintaining the 18 amps for any amount of time for the high current to do any damage to the insulation of the cord is not very great. Extension cords are only an extension of the 15 amp wall circuit that they are plugged into. On overloading the extension cord by that amount the overload will trip the 15 amp supply breaker. An example of this is jamming a circular handsaw when it is plugged into the end of a 50 foot extension cord. The next action that is taken is to reset the tripped breaker.


What is correct extension cord amp load for a 5500 volt generator?

Extension cords are not used at 5500 volts.


Can I use a 14AWG extension cord with a 8 amp car battery charger?

yes.


14 gauge extension cord will this work for microwave?

yes but could get hot or break the microwave.Look to see how many amps your microwave is.Also figure out what size breaker the outlet you are using is onlarger the wire in ext. cord the better especially at long distances.14 gauge = 15 amps12 gauge = 20 amps15 amp outlet with 12 gauge cord = 15 ampsI would use a 20 amp outlet with a 12 gauge ext. cordif going a long distance say 100 feet than better to have 10 gauge on 20 amp.your voltage goes down the longer the cord but with bigger wire it does not drop as fast.


I have a pop up camper and I am wanting to use an extension cord when the campers cord isn't long enough. The campers electrical system is 30amp and 110volt. Can I use a 13amp 125volt extension cord?

no, you should use same amp and volt.


Can you wire a 120 volt water heater with an appliance electrical cord to plug directly into a 15 amp outlet?

Circuits cannot be loaded to more than 80% of their rating. So if the wattage rating of the heater is more than 1440 you will need a 20 amp circuit and a 20 amp outlet Be careful what size cord you use. Most lamp cords and extension cords are not large enough to handle this heater. You must use a cord that has 14 gauge wires or larger for 15 amps and 12 gauge wire for 20 amps.


Is it safe to run 115 volt 1 hp single phase motor with 14 gauge cord the original cord is 14 gauge the switches in my source are all 15 amp.?

See Discuss Queston page


Can you replace a 10 amp 125 volt extension cord with a 10 amp 250 volt extension cord?

Yes the rated voltage is a maximum. A 250 v cord might be slightly thicker than one for 125 v. <<>> The voltage rating of an electrical extension cord is the insulation factor of the cord. These cords come in two insulation ratings, 300 volts and 600 volts. If the voltage rating is within the parameters of the cord maximums then it is safe to use it on that voltage. The amperage of the cord is based on the wire size of the cord's conductor. The rating of 10 amps will fall within the #14 cord size. Remember the longer the cord the larger the wire size should be to prevent voltage drop at the connected load end.