answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What is a dollar plate on a heat exchanger?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Where is the dollar plate on a heat exchanger?

It's the flat, flanged cover on the front (and sometimes the rear) of a shell & tube heat exchanger.


What is plate heat exchangers?

a plate heat exchanger is a metal plate which is will be in contact with another item eg air or another metal object to move heat from one to another


How to solve the failure of plate heat exchanger?

The plate heat exchanger has the characteristics of high heat transfer coefficient, small pressure drop, compact structure, light weight, small footprint, convenient area and process combination, strong versatility of parts, wide selection of materials, and simple completion of large-scale production. Widely used in the fields of food, machinery, metallurgy, petrochemicals and ships.In order to ensure the normal operation of the plate heat exchanger, it is particularly important to extend the service life of the plate heat exchanger components (such as plates and rubber pads), and to understand the problems and the causes of the plate heat exchanger and the treatment methods.Brazed Plate Heat ExchangerBrazed Plate Heat Exchanger Model ZL20BProblem:The plate heat exchanger has leakage (small amount, water droplets are not continuous) and leakage (large amount, water droplets are continuous). The primary parts of external leakage are the seal between the plate and the plate, the position where the plate seals the leakage groove, and the inner side of the end plate and the compression plate.The reason:The clamping scale is not in place, the scale across the ground is not uniform (the ground scale error should not be greater than 3 mm), or the clamping bolt is loose. Part of the gasket is separated from the sealing groove, the main sealing surface of the gasket is dirty, the gasket is damaged or the gasket is aging. The plate is deformed, and the misalignment causes the running mat.Solution:In the state of no pressure, clamp the equipment from the beginning according to the clamping scale supplied by the manufacturer. The scale should be uniform and common. The error of the compression scale should not exceed ± 0.2N (mm) (N. is the total number of plates) The parallelism should be kept within 2 mm. Make a symbol on the leakage part, and then check the heat exchangers one by one, and install or replace the gaskets and plates from scratch.YOJO can provide a variety of heat exchange equipment solutions for the failure of the plate heat exchanger. For leakage problems of the plate heat exchanger, if there are other questions, please contact YOJO.Tag: Heat exchange equipment solution, Heat exchange equipment, plate heat exchanger leakage


What is a plate heat exchanger used for?

Plate heat exchangers are used in combination boilers, also sometimes referred to a 'combi-boilers'. The plate heat exchanger is found inside the hot water section and uses metal plates to move heat between two fluids.


How do you clean welded plate heat exchanger?

Refluxing solvent is one way but an ultrasonic batch is better.


Is it correct that Plate Type Heat Exchangers can only handle very clean liquids practically free from any suspended particles as compared to Shell and Tube type Heat Exchanger?

It really depends on the fluid. If the fuild is taken into consideration when sizing the heat exchanger then there are times when a plate and frame can work. It really comes down to proper sizing.


Function of heat exchanger?

There are actually many types of plate heat exchangers, and the YOJO brand has introduced brazed plate heat exchangers and gasket plate heat exchangers. Today is the home of brazed heat exchangers.Brazed plate heat exchangers have no headers, tie rods or sealing gaskets, and the plates are brazed at a temperature of 1100 ° C. During the assembly stage, a piece of brazing material (usually copper, and nickel) is placed between the two plates, the package is compressed, and then baked for several hour.BPHE is more compact and lighter, and the brazing material has the functions of both washer and frame. The intersection between the corrugations of the two coupling plates forms a dense network of contact points, which impart pressure tightness and generate vortex flow, thereby improving heat exchange. In this way, even at low nominal input speeds, the turbulence of the fluid is high, and for low flow rates, the fluid flows from laminar to turbulent.


Heat exchanger for ammonia absorption refrigeration system?

there are two type of heat exchanger in absorption refrigeration, first is liquid heat exchanger and other is gas heat exchanger.both heat exchanger function is same, to transfer heat (hot medium to cold medium) without violate second newton law of thermodynamics. liquids heat exchanger is between boiler and absorber vessel mean while gas heat exchanger between evaporator and absorber.


What does a feed pump do in pasteurization of milk?

The feed pump promote the flow of raw milk from balance tank to plate heat exchanger.


How do you calculate the water flow requirements of a plate heat exchanger?

"http://wiki.answers.com/Q/How_do_you_calculate_the_water_flow_requirements_of_a_plate_heat_exchanger" "http://wiki.answers.com/Q/How_do_you_calculate_the_water_flow_requirements_of_a_plate_heat_exchanger"


Exchanger is not transfer heat why?

Heat exchanger manufacturers is an ISO 9001 certified company located in Coimbatore, Tamilnadu. The company started its functioning 2011 in, with a strong background in heat exchanger manufacturing. Our well-experienced and dedicated employees consistently thrive to serve our customers with the best heat exchanger solution. visit :: heatexchangersmanufacturers.in


What is heat exchanger duty?

The duty of a heat exchanger can be defined in an easy way as "The amount of heat exchanged from a fluid at a higher temperature to the fluid at lower temperature in unit time by a heat exchanger is called its duty"