Blank reading is the initial reading taken before adding the sample in the titration of iodine value. It represents the baseline value of the titrant solution without the presence of the sample. This reading is used to ensure accuracy in calculating the iodine value of the sample by subtracting it from the final reading after titration.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Chemistry

Why does blank titration shows the higher value compared to sample titration in iodine value?

In blank titration, no sample is present to react with the iodine solution, leading to an apparent excess of iodine. This can result in a higher value as all the iodine being counted towards the blank. In sample titration, the sample reacts with the iodine, leading to a lower amount of iodine available to react, resulting in a lower value compared to the blank titration.


Why do we carryout blank titration in argentometric titration?

Blank titration is carried out in argentometric titration to account for any impurities or contaminants present in the reagents used. By measuring the volume of titrant required to reach the endpoint in the blank titration, this value can be subtracted from the volume used in the actual titration to determine the accurate amount of titrant required to react with the analyte.


What is the role of blank in formol titration?

In formol titration, blank serves as a control to account for any background color or turbidity in the sample that could interfere with the endpoint detection. By subtracting the blank value from the sample titration values, a more accurate measurement of the analyte concentration can be obtained.


How do you prepare Wijs solution from iodine monochloride vial for determining the iodine value of a fatty acid?

To prepare Wijs solution from iodine monochloride vial, weigh a specific amount of the iodine monochloride into a flask, add glacial acetic acid, then add a small amount of iodine crystals and mix well until dissolved. The resulting solution is Wijs solution, which can be used for determining the iodine value of a fatty acid by titration with unsaturated bonds in the fatty acid.


What is the electronegative value of iodine?

The electronegativity value of iodine is 2.66 on the Pauling scale.

Related Questions

Why does blank titration shows the higher value compared to sample titration in iodine value?

In blank titration, no sample is present to react with the iodine solution, leading to an apparent excess of iodine. This can result in a higher value as all the iodine being counted towards the blank. In sample titration, the sample reacts with the iodine, leading to a lower amount of iodine available to react, resulting in a lower value compared to the blank titration.


Equation used to determine the iodine value?

The equation used to determine the iodine value of a substance is typically expressed as IV = (g of I2 consumed or added / weight of sample in grams) x 100. The iodine value is a measure of the degree of unsaturation in oils and fats, indicating the number of double bonds present in the fatty acid chains.


Why do we carryout blank titration in argentometric titration?

Blank titration is carried out in argentometric titration to account for any impurities or contaminants present in the reagents used. By measuring the volume of titrant required to reach the endpoint in the blank titration, this value can be subtracted from the volume used in the actual titration to determine the accurate amount of titrant required to react with the analyte.


What is the role of blank in formol titration?

In formol titration, blank serves as a control to account for any background color or turbidity in the sample that could interfere with the endpoint detection. By subtracting the blank value from the sample titration values, a more accurate measurement of the analyte concentration can be obtained.


What is Iodine value for Activated Carbon?

Iodine Value of Activated Carbon Apparatus: Volumetric flask, conical flask, beaker, burette, pipette, filter paper Reagents: * 0.1N Iodine solution ( 40 gm KI in 1 Ltr of Distilled water ). * 0.05N Sodium Thiosulphate solution (12.5 gm Na2S2O3.5H2O in 1 Ltr Distilled water) * 1% Starch solution * Activated carbon Procedure: I Standardisation of Iodine solution * Take 10c.c of 0.1N Iodine solution in conical flask. * Add 2 drops of Starch solution. * The pale yellow colour of Iodine Soln turns Blue. * Titrate with 0.05 N Sodium Thiosulphate till it becomes Colourless. * Burette reading corresponds to blank reading.(B) II * Weigh very accurately 0.2 gm of Activated carbon * Introduce it into the Iodine flask which should be completely dry * Add 40cc of 0.1N Iodine solution * Shake the flask for 4 minutes and filter it * Collect the filterate in a dry flask and Titrate 10cc of the filtrate against Standard Sodium thiosulphate solution using starch as indicator * Burette reading corresponds to (A) Calculations: Iodine value: C x Conversion factor; mg/gm Factor:Mol wt. of iodine (127) x normality of iodine x 40 / Wt. of carbon x Blank reading C=B-A This is dry basis test From Ishan Udyog Bhilai


How do you prepare Wijs solution from iodine monochloride vial for determining the iodine value of a fatty acid?

To prepare Wijs solution from iodine monochloride vial, weigh a specific amount of the iodine monochloride into a flask, add glacial acetic acid, then add a small amount of iodine crystals and mix well until dissolved. The resulting solution is Wijs solution, which can be used for determining the iodine value of a fatty acid by titration with unsaturated bonds in the fatty acid.


What is the electronegative value of iodine?

The electronegativity value of iodine is 2.66 on the Pauling scale.


How is iodine estimated in ccl4 and h2o layer?

Titrate each solution separately with solution of known concentration of sodium thiosulphate. The titre value will give the amount of thiosulphate reacted with iodine, hence you can find concentration of iodine.


How do you get accurate titration value?

To get an accurate titration value, ensure that all reagents are standardized and accurately measured, use an appropriate indicator, perform the titration slowly and carefully, and repeat the titration for consistency. Calibration and proper maintenance of equipment are also important for accuracy.


What is the pka value of iodine?

The pKa value of iodine is not a well-defined quantity because iodine is not an acid that readily donates protons. Its pKa value is not commonly reported.


How get the accutare titration value?

Titration value describes how accurately a substance is dissolved in another substance. In order to find this number, you need a pipette, a burette, and a volumetric flask.


Why avoid the light in determine iodine value experiment?

Avoiding light in the determination of iodine value is important because iodine is light-sensitive and can react with light, leading to inaccurate results. Light exposure can cause the iodine to degrade or evaporate, which would affect the measurement of the iodine value. By conducting the experiment in a dark environment, you ensure the accuracy and reliability of the iodine value determination.